Dell PowerEdge 1655MC Supplementary Manual page 9

Replacing the server module board
Hide thumbs Also See for PowerEdge 1655MC:
Table of Contents

Advertisement

Select the Mirroring Properties Menu and press <Enter> to view or modify the
4
mirroring mode.
The two installed SCSI drives are listed with their SCSI IDs:
SCSI ID
Device
0
Fujitsu
1
Fujitsu
NOTE: SCSI ID 0 may be secondary and SCSI ID 1 may be primary in some cases.
Write down which SCSI ID is primary and which one is secondary.
5
Select the primary drive and press the space bar to change the Status field to No.
6
Repeat this step for the secondary drive.
NOTE: Both the primary and secondary Status fields should be No.
Press <Esc> to exit the Mirroring Properties Menu.
7
Select Save changes and exit this menu and then press <Enter>.
8
Press <Esc> to exit the Adapter Properties Menu.
9
Press <Esc> to exit the Main Menu.
10
Select Exit the Configuration Utility and press <Enter>.
11
The server module reboots. During POST, the two SCSI drives are displayed as
nonmirrored, as shown in the following example:
HBA
ID
LUN
VENDOR PRODUCT
0
0
0
Fujitsu MAN3184MP
0
1
0
Fujitsu MAN3184MP
0
7
0
LSI Logic 1020/1030
Go to "Replacing the Server Module Board."
12
Identifier
MAN3184MP 5507
MAN3184MP 5A01
Mirrored Pair
Status
Primary
Secondary
REV
SYNC
5507
160.0
5A01
160.0
1000c00
320.0
Re plac ing the Se r ve r Mo dule Bo ard
WIDE
CAPACITY
16
18211 MB
16
18211 MB
16
1-5