For control from a PC, use Telnet, Putty, or similar programs to open the TCP connection. If you do not know the IP address of the MP-60 on your local network, the MP-60 supports Apple´s Bonjour Discovery service, which must be on the computer you want to set up the MP-60 with.
Control Via Serial Port The serial port on the MP-60 is wired as a DTE, so for communication with a PC or similar, you will need a null modem adapter and gender changer. The port settings should always be 8 data bits, no parity, one stop bit and no hardware handshake.
Feedback level 2: Each command is also echoed back with the ‘#’ in front of the command instead of ‘!’ character. For example, command “!VOL?<CR>” would return “#VOL?<CR>!VOL(XXX)<CR>”. Lyngdorf MP-60 – External Control Manual...
!DTSDIALOGAVAILABLE? Request the current X = 0: Not available, availability of DTS !DTSDIALOGAVAILABLE(X) otherwise X = 1 Dialog Control !DTSDIALOGDN DTS Dialog Control Down !DTSDIALOGUP DTS Dialog Control !ENTER Enter button !EXIT Exit button Lyngdorf MP-60 – External Control Manual...
Page 7
-20.0 dB) maximum volume setting !MAXVOL(X) -550 to -200 (= -55.0 to Sets the maximum -20.0 dB) volume !MENU Menu Button !MULTIVIEW Multiview button !MUTE Mute toggle button !MUTE? !MUTEON or Requests mute !MUTEOFF Lyngdorf MP-60 – External Control Manual...
Page 8
Repeated for all available X is the number of the Voicings voicing and “name” is the name of the position as a string. !SETUP Setup button !SRC- Previous source button Lyngdorf MP-60 – External Control Manual...
Page 9
X is between -100 (- Return center channel 10dB) and 100 (+10dB) level trim (10 = 1dB) !TRIMCENTER(X) X is between -100 (- Sets center channel 10dB) and 100 (+10dB) level trim (10 = 1dB) Lyngdorf MP-60 – External Control Manual...
Page 10
Returns a string with the current video input !VOL- Decrease volume !VOL-(X) -999 to 240 (= -99.9 to Decrease volume by x +24.0 dB) !VOL? !VOL(X) -999 to 240 (= -99.9 to Request current +24.0 dB) volume Lyngdorf MP-60 – External Control Manual...
Page 11
B volume !ZVOL(X) -999 to 240 (= -99.9 to Set zone B volume +24.0 dB) !ZVOL+ Increase zone B volume !ZVOL+(X) -999 to 240 (= -99.9 to Increase zone B +24.0 dB) volume by x Lyngdorf MP-60 – External Control Manual...
Commands !ZVOL+<CR>, !ZVOL-<CR>, !ZVOL+(X)<CR>, !ZVOL-(X)<CR>, !ZVOL(X)<CR>, !ZVOL?<CR>, !ZMUTEON<CR>, !ZMUTEOFF<CR> and !ZMUTE<CR> are used to control zone 2 volume the same way as the main zone volume. Lyngdorf MP-60 – External Control Manual...
Page 13
It is never possible to set the volume above the maximum volume level setting with control interface commands, but it is very easy to accidentally reach the maximum volume level. Lyngdorf MP-60 – External Control Manual...
0 and the index of the last source. This response is also sent automatically, when the source changes, if feedback level is 1 or higher. If main zone is off, the MP-60 will reply with the previous selected source. Zone 2: Sources on zone 2 are a subset of the sources set up for main zone.
Page 15
This response is also sent automatically, when the zone 2 source changes, if feedback level is 1 or higher. If zone 2 is turned off, the MP-60 will reply with the previous selected source. Commands !ZSRC+<CR> and !ZSRC-<CR> are used to select next or previous source.
Page 16
Controlling Processing Modes The MP-60 processor has controls for selecting processing modes, also called audio modes. Command !AUDMODEL?<CR> can be used to get a list of processing modes; how many are there and what they are named. For example, a response for command !AUDMODEL?<CR>...
!RPFOCS?<CR>. The installer might add or remove focus positions at any time, so it is recommended to update the list of selectable focus positions at least in every boot-up. Lyngdorf MP-60 – External Control Manual...
Commands !LIPSYNC+<CR> and !LIPSYNC-<CR> are used to adjust the lipsync trim value by 5ms or -5ms, respectively. Command !LIPSYNC(X)<CR> is used to set the lipsync trim directly. The valid value range for this command needs to be fetched from the MP-60 (see below).
1 or higher. Controlling Feedback Level It is possible to set the feedback level from the external control interface with command !VERB(X)<CR>, where X is the wanted feedback level 0, 1 or 2. Lyngdorf MP-60 – External Control Manual...
On Screen Menu when using a dedicated control interface. Direct controlling of HDMI outputs It is possible to control the HDMI outputs of the MP-60 controller directly using special control interface commands. The controlling allows routing of any HDMI input directly to either one of the HDMI outputs in bypass mode.
Need help?
Do you have a question about the MP-60 and is the answer not in the manual?
Questions and answers