Installation - Delfield EHEI36C Installation And Operation Manual

E-chef series hot food table
Table of Contents

Advertisement

E-Chef™ Series Installation and Operation Manual

INSTALLATION

Maximum weight for openshelves and
over shelves is 250 pounds. Overloading
shelves can damage equipment or cause
bodily injury.
INSTALLATION: ESSw36 & EODC36S SERIES (ELECTRIC)
Installation should only be done by personnel
certified and licensed to install and maintain
electrical appliances.
Location
Intended for indoor use only. Do not install the hot food table near
any combustible objects or surfaces affected by heat or moisture.
Flanged feet must be fastened to the floor.
Leveling
This unit must be level, both front and back and left to right, in
order to maintain an equal water depth throughout the wells.
INSTALLATION: ESIC36 & EODC36I SERIES
Plumbing
The unit's drain must have an outlet to an appropriate drainage
area or container. The 1" IPC piece drain is shipped loose and
must be connected during installation.
INSTALLATION: EHEI SERIES (ELECTRIC)
Installation should only be done by personnel
certified and licensed to install and maintain
electrical appliances.
Location
Intended for indoor use only. Do not install the hot food table near
any combustible objects or surfaces affected by heat or moisture.
Leveling
This unit must be level, both front and back and left to right, in
order to maintain an equal water depth throughout the wells.
4
For customer service, call (800) 733-8829, (800) 733-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com
Plumbing
A waste connection is provided 26.5" (67.3cm) above the floor,
1/2" from the gate valve. You must supply the required 1/2"
connection at gate valve.
Electrical connection
Connections must be made in accordance with all
applicable local codes and/or the National Electrical
Code. Refer to the wiring diagrams on page 10.
Plumbing
A waste connection is provided 26.5" (67.3cm) above the floor,
5.25" (13.3cm) from the right end. You must supply the required
1/2" connection at gate valve.
Electrical connection
Connections must be made in accordance with all
applicable local codes and/or the National Electrical
Code. Refer to the wiring diagrams on page 10.
Delfield
®

Advertisement

Table of Contents
loading