Fault
E:32-00 will light up altern-
ately or indicator for water
supply lights up.
E:92-40 will light up altern-
ately.
E:61-03 will light up altern-
ately. Water is not drained.
E:61-02 will light up altern-
ately.
Cause
The filters in the water con-
nection of the supply or
AquaStop hose are blocked.
Filters are soiled or blocked.
Wastewater hose is blocked
or kinked.
Siphon connection is still
sealed.
Cover of the wastewater
pump is loose.
Wastewater pump is
blocked.
Cover of the wastewater
pump is loose
Troubleshooting en
troubleshooting
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.
Remove the filter from the supply
5.
hose
Clean the filter.
6.
Re-insert the filter in the supply
7.
hose.
Screw the water connection back
8.
on.
Check the water connection for
9.
leaks.
Restore the power supply.
10.
Switch the appliance on.
11.
Clean the filters.
→ "Cleaning filters", Page 40
Reposition the wastewater hose
1.
without kinks.
Remove residues.
2.
Check the connection to the siphon
and open if necessary.
Secure the cover of the Wastewater
pump → Page 54 so it clicks into
position.
Clean the wastewater pump.
→ "Clean wastewater pump",
Page 54
Secure the cover of the Wastewater
pump → Page 54 so it clicks into
position.