TABLE OF CONTENTS page Introduction Installation Mounting Connections Methods of Converter Activation Power Limiting & Overload Protection III Internal Adjustments Voltage Adjustment IV Warranty Mechanical Drawing of Base Plate VI Electrical Specifications...
I Introduction Model 384 is shipped in fully assembled form. After removing the unit from its packaging and ensuring that it has suffered no damage in shipment, it is important to read this manual and follow its instructions to ensure proper connection and mounting.
2) Select the suitable method of converter activation. 2.3 Methods of Converter Activation A) Connect terminal #1 to terminal #2 on terminal block TBA. The 384 is so configured when shipped from the factory. This configuration allows for converter activation by either turning the source power ON and OFF.
III Internal Adjustments Varying the adjustments of the Model 384 require the technician to have a stable DC power supply variable from at least 20 VDC to 30 VDC. To access the adjustment, turn the unit upside down and remove the base plate by unscrewing the 4 securing screws in its corners.
IV Warranty and Repair Should your investigations indicate that your new Model 384 is defective or damaged and your unit is still under warranty then contact SEC America, LLC at 802-865-8388 and obtain return merchandise authorization for credit or exchange.
America Corp MODEL 384 Wide Input Range Down Converter 22 Vdc-60 Vdc to 13.6 Vdc / 60A Design Features - Low Input Voltage Cutout - Compact design - Convection Cooled - High Efficiency- 96% minimum - Common Input-Output Negative Terminal...
Need help?
Do you have a question about the 384 and is the answer not in the manual?