    711HS Series models are fully isolated dc-dc converters capable of delivering up to 720 Watts in extreme ambient temperatures and adverse operating conditions. See specification sheets at the end of this manual for the ratings of a particular model.
  • Page 4: Mechanical Drawing

    Figure 2 All dimensions are in inches III Regulation With Remote Sense 711HS Output Load Figure 3 twisted pair Connector   The HS Series provides regulated outputs at the output terminals. When there is a large current and/or the  output cable is of some length, the voltage at the end of the cable may be noticeably lower than at the  terminals. The converter can compensate up to 0.75V of voltage drop through remote sense terminals. To  ensure accurate regulation, users should run two separate wires (twisted from the desired regulation points to  the remote sense terminals. Even if the load current is low, users should still connect +Vo to +S and –Vo to –S.   Page 2...
  • Page 5: User Adjustments

    IV User Adjustments 711HS Series units are gasket-sealed. Changes or adjustments to the operating modes of any unit are accomplished internally: 1) To gain access, remove the 4 corner screws retaining the front connector plate as shown in Figure #4.
  • Page 6: Warranty

    (RMA number) for corrective action. If the warranty period has expired or if the warranty has been violated due to operator error or misuse call: SEC America Corp, 802-865-8388 to receive an authorization for return for an assessment and possible repair.
  • Page 7: Electrical Specifications

    No warranty or re- presentation by anyone other than this Company shall be binding on us. To return a unit to factory, send only to the following address: SEC America Corp 78 Ethan Allen Drive South Burlington, Vermont 05403 Tel: 802-865-8388 PLEASE RETAIN YOUR ORIGINAL BILL OF SALE.