Canon P/N 3106E24-11SB Figure 1 Figure 1A Pins Maximum Wire Sizes D,E,F Others An option for users who wish to purchase a manufactured cable assembly is P/N 68-0749-6 which is 6 feet long and is a standard SEC part. Page 1...
Figure 2 All dimensions are in inches III Regulation With Remote Sense DC-DC Load Figure 3 twisted pair Converter The HS Series provides regulated outputs at the output terminals. When there is a large current and/or the output cable is of some length, the voltage at the end of the cable may be noticeably lower than at the terminals. The converter can compensate up to 0.75V of voltage drop through remote sense terminals. To ensure accurate regulation, users should run two separate wires (twisted from the desired regulation points to the remote sense terminals. Even if the load current is low, users should still connect +Vo to +S and –Vo to –S. Page 2...
IV User Adjustments Series 600HS units are gasket-sealed. Changes or adjustments to the operating modes of any unit are accomplished internally: 1) To gain access, remove the 4 corner screws retaining the connector plate as shown in Figure #4. Disconnect power from the unit before opening it. Figure 4 2) After removing the screws, lift the panel to expose the internal components as shown.
(RMA number) for corrective action. If the warranty period has expired or if the warranty has been violated due to operator error or misuse call: SEC America, LLC, 802-865-8388 to receive an authorization for return for an assessment and possible repair.