Pos: null /BA_Module/BA_EA Sicherheitshinweise/BAEA000005_M002 @ 4\mod_1336032805351_28.docx @ 745180 @ 1 @ 1 1 General safety information Specified normal use The drive unit is intended for horizontally-driven folding doors. The safe operation is only guaranteed with normal specified use. The drive unit is to be protected from rain, moisture and aggressive ambient conditions.
Pos: null /BA_Module/BA_GA Mechanische Montage/BAGA006603_M001 @ 0\mod_1273581431158_28.docx @ 528695 @ 1 @ 1 3 Mechanical installation Prerequisites The permissible loads on walls, fastenings, mountings and transmission elements must not be exceeded, even for maximum holding torques or locking torques (▶ refer to technical data).
Page 7
Mounting Four holes are provided for mounting.
Page 8
Installation The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation. Warning - Potential injury or danger to life! During installation, be sure to use a lifting device that has a sufficient load- carrying capacity.
Pos: null /BA_Module/BA_HA Elektrische Montage/BAHA040101_M001 @ 0\mod_1222157034316_28.docx @ 83294 @ 1 @ 1 4 Electrical installation Warning - Danger to life from electric current! Switch the mains OFF and check that the cables are de-energised Observe the applicable regulations and standards ...
Pos: null /BA_Module/BA_IA Endschaltereinstellung/BAIA061131_M001 @ 0\mod_1263458810995_28.docx @ 477434 @ 1 @ 1 5 Limit switch adjustment Adjust the limit switches to define the final limits positions for OPEN and CLOSE. Prerequisite The door must open when the OPEN pushbutton is operated. If the door closes, L1 and L2 must exchanged with the current switched off.
Page 11
Check the position of the door: Close the door ① until the cam is free and open the door again ② at OPEN final limit position. Carry out fine adjustment to correct the OPEN final limit position. Check the door position after correction.
Pos: null /BA_Module/BA_UA Nothandbetätigung/BAUA000011_M001 @ 0\mod_1272469899528_28.docx @ 519911 @ 1 @ 1 9 Emergency manual operation lever The emergency manual operation is provided as a means of opening or closing doors that do not have electric power supply. Operation interrupts the control voltage. Electrical operation is no longer possible.
Pos: null /BA_Module/BA_WA Abschluss Inbetriebnahme/ Wartung/BAWA000102_M001 @ 0\mod_1212492526395_28.docx @ 14160 @ 1 @ 1 10 Completing commissioning / inspection Check the following components and then install all covers. Gearbox Check the drive unit for loss of oil (a few drops can be neglected). Protect the output-shaft permanently against corrosion.
EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Machinery Directive 2006/42/EC are met: 1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2,...