Low Flame Adjustment - Fisher & Paykel DCS GDSBE1-30 Installation Manual

Double side burner/griddle
Table of Contents

Advertisement

The valves on the double side burner/griddle unit feature an adjustable low setting. Due to fluctuations in gas pressure, or heating value you may feel it necessary to increase or decrease gas flow in
the low position. If the gas type has been converted from natural to LP or vice-versa, the low flame setting must be reviewed and adjusted.
1
2

LOW FLAME ADJUSTMENT

Push in and hold the selected dial
for two seconds before turning to
HI. Hold for 10 seconds to light the
selected burner.
Turn the control dial counter-
clockwise to the lowest setting.
3
4
BEZEL FRONT VIEW
Remove the dial.
While holding the valve shaft with
pliers, insert a flat-tipped screwdriver
into the shaft and, while viewing the
burner, adjust to a minimum stable
flame.