20 INSTALLATION
NOTE
• Gently press the collet and insert the tube until
only one line shows on the tube.
6
Place the cover
i
the cover screw
j

Connecting the Water Line

Before Beginning
This water line installation is not covered by the
refrigerator warranty. Follow these instructions
carefully to minimize the risk of expensive water
damage.
If necessary, call a qualified plumber to correct
water hammer before installing the water supply
line to the refrigerator. Water banging in the
pipes, or water hammer in residential plumbing
can cause damage to refrigerator parts and lead to
water leakage or flooding.
• Turn the icemaker OFF if the refrigerator will be
used before the water line is connected.
• Do not install the icemaker tubing in areas
where the ambient temperatures fall below
freezing.
WARNING
• Connect to potable water supply only.
in place. Insert and tighten
.
CAUTION
• To prevent burns and product damage, only
connect the refrigerator water line to a cold
water supply.
• Wear eye protection during installation to
prevent injury.
Water Pressure
You will need a cold water supply.
Water Pressure
models with water
filter
where reverse
osmosis water
filtration system is
connected to a cold
water supply
If the water pressure from the reverse osmosis
system is less than 20 psi or 138 kPa or 1.4 kgf/
2
cm
(takes more than 4 seconds to fill a cup of 7 oz
or 198 cc capacity):
• Check to see if the sediment filter in the reverse
osmosis system is blocked. Replace the filter if
necessary.
• Allow the storage tank on the reverse osmosis
system to refill after heavy usage.
• If the water pressure remains low, call a
licensed, qualified plumber.
• All installations must be in accordance with local
plumbing code requirements.
Supplies Needed
• Copper or PEX Tubing, ¼ in. outer diameter, to
connect the refrigerator to the water supply. Be
sure both ends of the tubing are cut square. To
determine how much tubing you need, measure
the distance from the water valve on the back of
the refrigerator to the water supply pipe. Then,
add 8 feet (2.4 m). Be sure there is sufficient
extra tubing (about 8 feet [2.4 m] coiled into 3
turns of about 10 in. [25 cm] diameter) to allow
the refrigerator to move out from the wall after
installation.
• Power drill.
• ½ in. or adjustable wrench.
• Flat-blade and Phillips-head screwdrivers.
20 - 120 psi (138 - 827 kPa)
40 - 60 psi minimum to
reverse osmosis system
2
(2.8 kgf/cm
- 4.2 kgf/ cm
or less than 2 - 3 seconds to
fill a cup of 7 oz capacity)