Connecting The Water Line - LG LS66SXNC Owner's Manual

Table of Contents

Advertisement

INSTALLATION
16
3
Lift the fridge door until it is free of the bottom
hinge assembly.
CAUTION
• Place the door on a non-scratching surface with
the inner side facing up.
Refitting the Fridge and Freezer
Door
Refit the doors in the reverse sequence of their
removal once the appliance has been passed
through all access doors.
CAUTION
• Install the fridge door first.
NOTE
• Disassembling/Assembling the water lines
Collet
Tube
a
b
c
• Gently insert the tube until only one of the tube's
lines is visible. Pull on the tube to make sure that
it is tightly fastened.
Insert line
Clip
d
Correct
Incorrect
• If the water tube end is damaged, it should be
trimmed to ensure it does not leak when refitted.
Not straight
Damaged
e
f

Connecting the Water Line

This feature is only available on some models.
Water Supply Requirements
A cold water supply with water pressure between
138 kPa and 827 kPa (1.4-8.4 kgf/cm²) is required to
operate the water dispenser. If the refrigerator is
installed in an area with low water pressure (below
138 kPa), you can install a booster pump to
compensate for the low pressure.
If a reverse osmosis water filtration system is
connected to your cold water supply, the water
pressure to the reverse osmosis system needs to
be a minimum of 138 kPa to 827 kPa (1.4-8.4 kgf/
cm²)
WARNING
• Unplug the appliance before carrying out any
work on connecting the water line. Failure to do
so may cause electric shock.
• Only connect the water line to a cold water
supply. Failure to do so may cause the water
filter to malfunction. Water hammer (water
banging in the pipes) in house plumbing can
Stretched
g

Advertisement

Table of Contents
loading