Where To Install The Speciality Unit
Place the speciality unit as close as possi-

ble to the pressure tank (well system) or
water meter (city water).
Place the Speciality System as close as

possible to a floor drain, or other accepta-
ble drain point (laundry tub, sump, stand-
pipe, etc.).
Connect the Speciality System to the main

water supply pipe BEFORE the water heat-
er.
DO NOT RUN HOT WATER
THROUGH THE SPECIALITY SYSTEM.
Temperature of water passing through the
Speciality System must be less than 100
deg. F.
Keep outside faucets on hard water to

save soft water and salt.
Do not install the Speciality System in a

place where it could freeze. Damage
caused by freezing is not covered by
the warranty.
Put the Speciality System in a place water

damage is least likely to occur if a leak de-
velops. The manufacturer will not repair or
pay for water damage.
A 120 volt electric outlet, to plug the in-

cluded transformer into, is needed within 6
feet of the Speciality System. The trans-
former has an attached 6 foot power ca-
ble. Be sure the electric outlet and
transformer are in an inside location,
to protect from wet weather.
If installing in an outside location, you

must take the steps necessary to assure
the Speciality System, installation plumb-
ing, wiring, etc., are as well protected from
the elements, contamination, vandalism,
etc., as when installed indoors.
Keep the Speciality System out of di-
