1. Read all instruc ons carefully before opera on.
2. Avoid pinched o‐rings during installa on by applying (provided with install kit) NSF cer fied lubri‐
cant to all seals.
3. This system is not intended for trea ng water that is microbiologically unsafe or of unknown
quality without adequate disinfec on before or a er the system.
4. Backwash for 30 minutes a er installing in order to allow the layers to se le to their appropriate
height.
REVISION #
0
REVISION DATE March 17, 2017
80150386
785 HIMTLC PLUS
Canadian Head Office
855 Park St.
Regina, SK. S4N 4Y4
U.S. Head Office
9760 Mayflower Park Drive,
Suite 110
Carmel, IN 46032

Advertisement

Table of Contents
loading

Summary of Contents for Canature 785 HIMTLC PLUS Series

  • Page 1 785 HIMTLC PLUS 1. Read all instruc ons carefully before opera on. 2. Avoid pinched o‐rings during installa on by applying (provided with install kit) NSF cer fied lubri‐ cant to all seals. 3. This system is not intended for trea ng water that is microbiologically unsafe or of unknown quality without adequate disinfec on before or a er the system.
  • Page 2: Unpacking Inspection

    Table of Contents PAGE Unpacking / Inspection Safety Guide Proper Installation Specification Before Starting Installation Installation Instructions System Start Up Programming Instructions About The System Maintenance Sanitizing Procedure Main Repair Parts Trouble Shooting Warranty Unpacking / Inspection Be sure to check the entire Speciality system for any shipping damage or parts loss. Also note damage to the shipping cartons.
  • Page 3: Proper Installation

    Proper Installation This Speciality system must be properly installed and located in accordance with the Installation Instructions before it is used. Do not install or store where it will not be psi, night time pressure may exceed the  exposed to temperatures below freezing or maximum.
  • Page 4: Specifications

    Specifications HIMTLCPLUS- HIMTLCPLUS- HIMTLCPLUS- HIMTLCPLUS- Specifications Salt Used - Per Regeneration 9.0 lbs 12.0 lbs 15.0 lbs 18.0 lbs Water Used - Regeneration 74.6 gal 98.9 gal 126.6 gal 153.0 gal Hardness Removal - Grains 17,100 22,800 28,500 34,200 Advanced Exchange Media (ft3) 1.32ft 1.76 ft 2.20 ft...
  • Page 5 Where To Install The Speciality Unit Place the speciality unit as close as possi- the warranty.  ble to the pressure tank (well system) or Put the Speciality System in a place water  water meter (city water). damage is least likely to occur if a leak de- Place the Speciality System as close as velops.
  • Page 6: Before Starting Installation

    Before Starting Installation Tools, Pipe, and Fittings, Other Materials Pliers pipe.  Screwdriver ALWAYS install the included bypass valve,   Teflon tape or 3 shut-off valves. Bypass valves let you  Razor knife turn off water to the Speciality System for ...
  • Page 7 Clean / Soak Procedure Add 3‐4 gallons of water to brine tank. (Be sure that salt level is above water level at all mes) 2. Allow minimum 2 hours for the water to absorb the salt. 3. Start a manual regenera on. 4.
  • Page 8: Installation Instructions

    Installation Instructions 1. If your hot water tank is electric, turn off the power to it to avoid damage to the element in the tank. 2. If you have a private well, turn the power off to the pump and then shut off the main wa- ter shut off valve.
  • Page 9: Installation

    Installation...
  • Page 10: Key Pad Configuration

    System Start-Up Key Pad Configuration SETTINGS This func on is to enter the basic set up infor‐ ma on required at the me of installa on. MANUAL This func on is to ini ate an immediate or REGEN delayed manual regenera on. DOWN / Increase or decrease the value of the se ngs while in the programming mode.
  • Page 11: Programming Instructions

    Programming Instructions TIME DAY, YEAR, For SIM units choose IRON & MONTH, DAY, Time of day is for normal op- eration of system and the WATER TYPE scheduling of the regenera- Select WELL / OTHER if any tion time. The date is used Iron or Manganese is present in a diagnostic function to or if the water source is not...
  • Page 12: About The System

    About The System Control Operation During A Power Failure In the event of a power failure, the valve will keep track of the time and day for 48 hours. The programmed settings are stored in a non-volatile memory and will not be lost during a power failure.
  • Page 13: System Configuration

    Regeneration Process When the system capacity is near exhausted, a regeneration is necessary to restore the sys- tem to full capacity. The table below explains the regeneration steps. Automatic Hard Water Bypass During Regeneration The regeneration cycle can last 30 to 180 minutes, after which soft water service will be re- stored.
  • Page 14: Manual Bypass

    Manual Bypass In the case of emergency, such as an overflowing brine tank, you can isolate your water Speciality System from the water supply using the bypass valve located at the back of the control. In normal operation the bypass is open with the on/off knobs in line with the inlet and outlet pipes.
  • Page 15 Cleaning or Replacing Injectors Sediment, salt and silt will restrict or clog the injector. A clean water supply and pure salt will prevent this from happening. The injector assembly is located on the right side of the control valve. This assembly is easy to clean.
  • Page 16 Main Repair Parts - Connectors 21363...
  • Page 18 Replacing Brine Line Flow Control (BLFC) TIP: Markings on the BLFC washer should face the direction as shown here. 1. Remove the red clip that secures the brine elbow. 2. Remove the BLFC holder from the elbow fitting. 3. Split the BLFC holder apart and remove the flow washer. 4.
  • Page 19: Care Of Your System

    Care of Your System To retain the attractive appearance of your new water Speciality System, clean occasionally with mild soap solution. Do not use abrasive cleaners, ammonia or solvents. Never subject your specialty system to freezing or to temperatures above 100°F. Resin Cleaner DO NOT USE any resin cleaners.
  • Page 20: Control Valve Exploded View

    Control Valve Exploded View VALVE REPAIR PARTS LIST Replacement Replacement Part Description Part Description Part Number Part Number 60010127 INJECTOR SET #0000 BLACK 60010129 85HE UPFLOW PISTON ASSEMBLY 60010126 INJECTTOR SET #000 GREY 60010171 85HE DOWNFLOW PISTON ASSEMBLY 60010035 INJECTOR SET #00 VIOLET 60010130 85HE SEAL &...
  • Page 22 Power Head Exploded View...
  • Page 23: Power Head Parts List

    Power Head Parts List 785HE POWER HEAD (DOWNFLOW) Replacement MFG Part Number Part Description DWG # Quantity Part Number 60010574 Screw-ST3.5X13 60010673 Screw-ST2.9X10 Screw-ST3.5X25 BNT85HE Piston Rod Guide Plate 60010050 Motor-12v/2rpm 97000967 Motor Power Cable 60010660 Motor Pin 60010573 BNT85HE Mounting Plate 92389 BNT85 Drive Gear 60010099...
  • Page 24: Troubleshooting

    Trouble Shooting...
  • Page 25: Warranty

    Seven Year Complete Parts Guarantee Canature WaterGroup will replace any part which fails within 84 months from date of manufacture, as indicated by the serial number, provided the failure is due to a defect in material or workmanship. The only exception shall be when proof of purchase or installa- tion is provided and then the warranty period shall be from the date thereof.

Table of Contents