E462 : Current Protection Control Causes Comp. Down; E484 : Pfc Overload Errorr - Samsung AC200KNHPKH Service Manual

Hide thumbs Also See for AC200KNHPKH:
Table of Contents

Advertisement

4-3-18 E462 : Current protection control causes comp. down

E484 : PFC overload error
Outdoor unit display
Criteria
Cause of problem
1.
How to check
Compressor input voltage supplied ok?
Overcurrent option setting ok?
Samsung Electronics
E462,E484
• The outdoor machine input current above I_Trip.
•Check the compressor input voltage. (error for low voltage.)
•Check the overcurrent option setting.
Yes
Finished inspections
No
Check the input power terminal.
No
Correct the overcurrent setting.