Compex EDGE 2.0 User Manual

Compex EDGE 2.0 User Manual

Muscle stim + tens

Advertisement

EDGE 2.0
M U S C L E STI M + TE N S
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EDGE 2.0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Compex EDGE 2.0

  • Page 1 EDGE 2.0 M U S C L E STI M + TE N S...
  • Page 2: Table Of Contents

    WHOE SHOULD USE THE COMPEX? . . . . . . . . . . . . . . . . . .
  • Page 3 TABLE OF CONTENTS DEVICE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-31 PRELIMINARY SETTINGS .
  • Page 4: Foreword

    Compex® Edge. It contains general instructions for operation, precautionary instructions, and maintenance recommendations. In order to obtain maximum life and efficiency from your Compex Edge, and to assist in the proper operation of the unit, read and understand this manual thoroughly.
  • Page 5: Glossary Of Medical Terminology

    Glossary of Medical Terminology Abdominal or Inguinal Hernia: Occurs when a portion of the abdomen (usu- ally fat or small intestine) bulge through a weak area of the abdominal wall. Acute Trauma: An injury resulting from a single event. Aerobic Metabolism: When the body is able to use oxygen to generate energy for the body.
  • Page 6 Glossary of Medical Terminology Ischemia: a lack of blood supply to an organ or other part of the body. Usually affects the heart muscles Lactic Acid: Waste left in the muscle after working at a high level of exercise for an extended period of time.
  • Page 7: Indications For Use

    INDICATIONS FOR USE The Compex Edge EMS is used for: The Compex Edge is intended to stimulate healthy muscles in order to improve or facilitate muscle performance. The work imposed on the muscles by the Compex Edge programs is definitely not suitable for rehabilitation and physiotherapy.
  • Page 8: Safety Information

    Safety Information PRECAUTIONARY INSTRUCTIONS Some instructions found in this section and throughout this manual are indicated by specific symbols. Understand these symbols and their definitions before operating this equipment. The definitions of these symbols are as follows: DANGEROUS VOLTAGE Text with a “Dangerous Voltage” indicator serves to inform Contraindications the user of possible hazards...
  • Page 9 Do not use the Compex Edge if you have one or more of the following medical conditions: • The Edge must not be used on persons with cardiac pacemakers, defibrillators, or other implanted metallic or electronic devices.
  • Page 10 Safety Information • Physician Care: If you are in the care of a physician, consult with your physician before using the Edge. • Physician Care: If you have had medical or physical treatment for your pain, consult with your physician before using the Edge.
  • Page 11 Safety Information • Head: Since the effects of stimulation of the brain are unknown, stimulation from the Edge should not be applied across your head and electrodes should not be placed on the opposite sides of the head. • Chest: The Edge stimulus is delivered by the waveforms of this device, in certain configurations, will deliver a charge of 25 microcoulombs (µC) or greater per pulse and may be sufficient to cause electrocution.
  • Page 12 Edge during a session while the stimulator is switched on. Switch the stimulator off first. • Medical Equipment: Do not use the Compex Edge if you are connected to a high-frequency surgical instrument as this could cause skin irritation or burns under the electrodes.
  • Page 13 Safety Information • Charging: Never use the Compex Edge or the charger if it is damaged (case, cables, etc.) or if the battery compartment is open. There is a risk of electric shock. • Charging: Disconnect the charger immediately if the Compex Edge “bleeps”...
  • Page 14: Cautions

    Safety Information PRECAUTION • Read, understand, and practice the precautionary and operating instructions found in this manual. Know the limitations and hazards associated with the treatment table. Observe any and all precautionary and operational decals placed on the unit. • Medical Equipment: DO NOT operate this unit in an environment where other devices are being used that intentionally radiate electromagnetic energy in an unshielded manner.
  • Page 15 • Accessories: Use only accessories that are specially designed for the Compex Wireless USA. Do not use accessories manufactured by other companies on the Wireless USA. DJO, LLC is not responsible for any consequence resulting from using products manufactured by other companies.
  • Page 16 • Only use electrodes supplied by DJO, LLC. Other electrodes may have electrical properties that are unsuitable for the Compex Edge stimulator. • Do not use electrodes with a surface < 19 cm² (2.94 in²), as there will be a risk of suffering a burn injury.
  • Page 17: Adverse Reactions

    SAFETY GUIDE PRECAUTION PRECAUTIONS WHEN USING ELECTRODES CONT. • Self-adhesive electrodes should be replaced if they no longer stick firmly to the skin. • Some people with very sensitive skin may experience redness under the electrodes after a session. Generally, this redness is completely harmless and disappears after 10 to 20 minutes.
  • Page 18: Whoe Should Use The Compex

    If you answer “Yes”, or “Maybe” , or “I don’t know” to one or more questions, do not use the device and contact DJO, LLC for more information. If you have 15 “No” answers, you can use the Compex Edge. DJO, LLC...
  • Page 19: Introduction

    In other words, the muscle cannot distinguish whether the command comes from the brain or from the stimulator. The parameters of the Compex Sport Elite programs (number of impulses per second, contraction time, rest time, total program time) subject the muscles to different types of work, according to muscular fibers.
  • Page 20: Benefits Of Electrostimulation

    INTRODUCTION BENEFITS OF ELECTROMUSCULAR STIMULATION (EMS) Electrostimulation is a very effective way to make your muscles work: • with significant improvement of different muscular qualities • without cardio-vascular or mental fatigue • with limited stress on the joints and tendons. Electrostimulation thus allows a greater quantity of work by the muscles compared with voluntary activity.
  • Page 21: Device Description

    Device Description COMPEX EDGE NOTE: You are strongly advised to carefully read the safety precautions and contraindications described at the start of this manual prior to using your stimulator. On/Off button “i” button used to: increase stimulation energies in several...
  • Page 22: Accessories

    Device Description ACCESSORIES Compex Edge stimulator Battery charger Set of electrode cables (blue/ green/ yellow/ red) Electrodes- 4 - 2x4" Dual Snap and 8 - 2x2" Single Snap Travel pouch...
  • Page 23: Programs

    Endurance The Compex Endurance program imposes an average medium working level on muscle fibers. This working level is maintained over a long period (40 minutes per session). The Endurance program particularly activates the aerobic metabolism of the fibers during the stimulation session.
  • Page 24: Specialized Muscle Training Programs

    Device Description B . SPECIALIZED MUSCLE TRAINING PROGRAMS The Compex Edge also offers one special muscle training program. The objective is to facilitate recovery after active muscle training and competition: • Training Recovery Training Recovery The Compex Active Recovery cool-down program produces muscle twitches at a very low frequency.
  • Page 25: Device Set Up

    DEVICE SET UP USAGE GUIDELINES The usage guidelines presented in this section should be considered as general rules. For all programs, it is recommended that you read carefully the usage information and advice presented in the Operation section. You should use the compexusa.com web site to establish an appropriate training plan.
  • Page 26: Electrode Positions And Tips

    The goal is to progress through the electrical intensities and then through the levels. The more numerous the muscle fibers you stimulate, the more numerous will be the fibers that are going to progress. But the speed of progress of these fibers and their aptitude for operating at a higher rating depend on the program and level used, the number of sessions per week, the length of these sessions and on intrinsic factors specific to each individual.
  • Page 27: Connecting The Cables To The Stimulator

    DEVICE SET UP ELECTRODE POSITIONS AND TIPS (CONT .) Clean and degrease the skin with an alcohol swab or cotton ball with alcohol and then dry it before applying the pads. For hygiene purposes, do not share your pads with others. When removing your pads from your skin, peel from the side of the pad.
  • Page 28: Device Operation

    Before using the unit for the first time, you should select the working language of the device which is displayed on the options screen. Follow the instructions below. Afterwards, for the greatest comfort, the Compex Edge offers you a number of setting options (operating language selection, display contrast setting, adjusting backlighting and volume setting).
  • Page 29: Selecting A Program

    DEVICE OPERATION SELECTING A PROGRAM To choose a program, it is particularly useful to consult "Programs" in the Operation section or to go on the compexusa.com web site as it offers an advanced interactive way to establish an appropriate work program. Press the On/Off button to switch off the unit.
  • Page 30 DEVICE OPERATION Press the On/Off button to return to the previous screen. Some programs require manual selection of the muscle group you want to stimulate. This muscle group is shown in black on a small figurine above channel 1. Use the Channel 1 +/- button to select your chosen group. The seven muscle groups proposed are shown successively in black on the small figurine.
  • Page 31: During The Stimulation Session

    Press the On/Off button to place the unit in Pause mode. B/C/D/E The Compex Edge "bleeps" and the symbols of the four channels flash, changing from + to 000: the four channels are at 000 energy. You must increase the stimulation energy so that the stimulation can start.
  • Page 32: Program Progression

    These can be modified during the rest phase. Once modified, they will be totally independent of the contraction energies. NOTE: If your Compex Edge emits a beeping sound and the symbols under the active channels begin to flash, the stimulator is suggesting you increase the level of the stimulation energies.
  • Page 33: End Of Program

    Never recharge the stimulator without first disconnecting the stimulation cables. Always use the charger supplied by DJO, LLC to recharge the batteries. The Compex Sport Elite has considerable operating autonomy, as it uses rechargeable batteries. The battery’s life depends on the programs and stimulation energy used.
  • Page 34: Recharging The Device

    1 hour 30 minutes). The battery icon is animated while the battery is recharging. When fully charged, the icon will be full and the total time taken to recharge the battery will flash on the screen. Simply disconnect the charger- the Compex Edge will turn off automatically.
  • Page 35: Specifications

    Do not sterilize the stimulator. To clean your unit, use a soft cloth and an alcohol- based cleaning product, which does not contain solvents. Solvents could damage the plastic parts, especially the panel covering the screen of your Compex Edge. Use only a minimum amount of liquid when cleaning the unit.
  • Page 36: Disposal

    STANDARDS The Compex Edge complies with current medical standards. To guarantee your safety, the Compex Edge has been designed, manufactured, and distributed in compliance with the requirements of European Directive 93/42/EC on medical devices. The Compex Edge also complies with the IEC 60601-1 standard on general...
  • Page 37: Description Of Device Markings

    SPECIFICATIONS DESCRIPTION OF DEVICE MARKINGS See the instructions Manufacturer’s name and address and date of manufacture Refer to Instruction Manual / Booklet / Website (www.ShopCompex.com) The stimulator is a Category II device with built-in power supply and BF Type parts Store in a dry place Class II Device with internal electric power On the unit means: Protected against solid bodies with a diameter equal to or...
  • Page 38: Output Waveform

    SPECIFICATIONS OUTPUT WAVEFORM Biphasic rectangular impulse with electrical mean equal zero (net zero DC). All electrical specifications are given for an impedance of 500-1000 ohms per channel. Channels: Four independent and individually adjustable channels that are electrically isolated from each other and earthed. UNIT CHARACTERISTICS Body: plastic...
  • Page 39 BY THE MANUFACTURER CONCERNING ELECTROMAGNETIC EMISSIONS The Compex Edge is intended for use in the electromagnetic environment specified below. The customer or the user of the Compex Edge should assure that it is used in such an environment. Electromagnetic Environment...
  • Page 40: Electro Magnetic Capability Tables

    BY THE MANUFACTURER - ELECTROMAGNETIC IMMUNITY The Compex Edge is designed for use in the electromagnetic environment stipulated below. The customer or the user of the Compex Edge must ensure that it is used in this recommended environment. Electromagnetic IEC 60601...
  • Page 41 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Compex Edge are used exceeds the applicable RF compliance level above, the Compex Edge should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the Compex Edge.
  • Page 42 AND THE COMPEX EDGE The Compex Edge is designed for use in an electromagnetic environment in which radiated RF waves are controlled. The buyer or user of the Compex Edge can contribute to preventing electromagnetic interference by maintaining a minimum...
  • Page 43: Troubleshooting

    Electrode Fault Symbol The Compex Edge "bleeps" and alternatively displays the symbol of a pair of electrodes and an arrow pointing to the channel where a problem has been detected. In the example above, the stimulator has detected an error in channel 1.
  • Page 44 TROUBLESHOOTING STIMULATOR IS NOT WORKING Error Messages If an error screen appears while you are using the device, note the menus and error number (in the example above, menus 1/0 and error 1/0/0) and contact the nearest authorized customer support service. NEED FOR RECHARGING If the symbol normally displayed above the channel 4 +/- button is not...
  • Page 45: Warranty

    WARRANTY DJO, LLC ("Company"), warrants that the Compex Edge ("Product") is free of defects in material and workmanship. This warranty shall remain in effect for two years (24 months) from the date of original consumer purchase. If this Product fails to function during the two year warranty...
  • Page 46 INDEX Choice Abdomen, 20 Feet, 20 Body Parts, 20 Accessories Forearms, 20 Confirming, 20 Foreword, 1 Description, 11, 33 Language, 19 Active Recovery, 26 Levels, 20 Adjusting Guidelines, Operational, 27-29 Program, 19, 27 Cleaning, 30 Backlight, 19 Connections Hands, 20 Contrast, 19 Help, 31 Stimulation, 21, 29...
  • Page 47: Index

    INDEX Muscle Group, 20 Nomenclature, 10-11 Safety Guide, 14-17 Off, 19 Screens Parameter Setting, 19 “On/Off” Backlight, 19 Adjusting Stimulation, 21 Programs, 19 “On/Off” Switch, 10, 19, 21-22, Battery Consumption, 24 Program Time, 21-22 Electrode Fault, 38 Recharging, 24, 39 Operation, 18-26 End of Program, 23 Relaxation, 22...
  • Page 48 P/N: 13-3541 REV A 10-15-2017 DJOglobal.com ©2016 DJO, LLC. All rights reserved.

Table of Contents

Save PDF