TRANSTEK LS202-B1 User Manual

TRANSTEK LS202-B1 User Manual

Body fat analyzer

Advertisement

Quick Links

Contains FCC ID: OU9AW8001-LS
GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD
Zone A, 5/F., Investment Building, No. 12, Huizhan East Rd., Torch Development
District, Zhongshan, Guangdong, 528437, China
TEL:86-760-88282982
www.transtek.cn
User Manual
Body Fat Analyzer
Thank you very much for selecting the Transtek Body Fat Analyzer
LS202-B1.
Please do read the user manual carefully and thoroughly so as to ensure
the safe usage of this product, and keep the manual well for further
reference in case you have problems.
version:1.0
LS202-B1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS202-B1 and is the answer not in the manual?

Questions and answers

Summary of Contents for TRANSTEK LS202-B1

  • Page 1 User Manual Body Fat Analyzer LS202-B1 Thank you very much for selecting the Transtek Body Fat Analyzer Contains FCC ID: OU9AW8001-LS LS202-B1. GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD Please do read the user manual carefully and thoroughly so as to ensure Zone A, 5/F., Investment Building, No.
  • Page 2: Table Of Contents

    Table of Contents Table of Contents Safety Information ....................Safety and Usage Information ............................Tips Overview ......................... Device Components ............................List ..........................LCD Display Initial Start-Up ......................... General Instructions ........................... Power Supply ........................Insert the Batteries ............................. Pair-up ......................... Set Up Your Profile ......................
  • Page 3: Safety Information

    CAUTION Always start measurement in the same time slot and on the same scale located on the Transtek’s Body Fat Analyzer LS202-B1 offers you a seamless way to manage your same flat, hard surface. health. Please be aware that this device is designed for healthy population over 10 years old For maximum accuracy and repeatability , it is recommended that you should use the self-measuring and self-monitoring body compositions.
  • Page 4: Overview

    Kilogram User Interface: Setting Pound List Male User ID (Range from U1 to U8 ) 1. Body Fat Analyzer LS202-B1 Female Successful Bluetooth Connection 2. Four AAA-size Batteries (1.5V each) Data transmitting / pending to 3. User Manual Male Athlete...
  • Page 5: Initial Start-Up

    General Instructions Pair-Up Transtek Body Fat Analyzer LS202-B1 applies BIA (Bio-impedance Analysis) technology. With the advanced Bluetooth 4.0 technology applied, the mobile or portable equipments, A small amount of weak current flows through the human body so as to detect the which are equipped with Bluetooth function in line with BLE Technical Specifications bio-impedance and estimate BMI, body fat, body water, muscle mass and bone mass.
  • Page 6: Set Up Your Profile

    Initial Start-Up Initial Start-Up Set Up Your Profile The body fat analyzer LS202-B1 supports multiple users (Up to Eight). You may follow 4.Setting Age below instructions to assign User ID and set up your own profile, including Gender, Stature, and Age.
  • Page 7: Initialising Your Scale

    LCD stop displaying moving “ ”. Weight Only Operation Your TRANSTEK Body Fat Analyzer will operate as a conventional weight - reading scale. No special programming steps are required. STEP 3: The measuring results will be displayed sequentially four times:BMI, Body Once the scale is initialized, as previously described, you may simply step on Fat, Muscle Mass,Total Body Water, Bone Mass, Weight, and then turn off.
  • Page 8: Daily Measurement

    Fast Measurement With batteries correctly installed, press “SET” key to turn on the scale, and the LCD With original SENSE ON patent technology, LS202-B1 will switch on as you step displays 0.0, then you may touch the function key to select the User ID.
  • Page 9: Manage Your Health

    Manage Your Health Troubleshooting Error Prompt Data Transmission Error Description Solution With LS202-B1 successfully pair-up with your smartphone, the measurement data will be Overload. The device will Stop using this scale for transmitted to your mobile via Bluetooth. power off. measurement.
  • Page 10: When Data Transmitting

    Troubleshooting Troubleshooting Problem Root Cause Solution When Data Transmitting ... Abnormal Problem Root Cause Solution measuring results: - Too high; OR Wipe your feet with a damp Turn ON the Bluetooth via Either your hands or your - Too low; OR Bluetooth is OFF.
  • Page 11: Specifications

    Temperature: -20℃ to 60℃ Humidity: ≤93% RH Storage Environment Transtek warrants its products free of defects in materials and workmanship in normal Atmospheric pressure: 50kPa to 106kPa use for a period of FIVE years from the date of retail purchase.
  • Page 12: Fcc Regulations

    FCC Regulations Appendix Table of Body Fat Level (Unit: %) FCC Regulations a) The body fat percentage (%): 5%-60%/0.1% Standard for Men Standard for Women FCC User Guide Information Radio Frequency Interface Requirements - FCC Rating Rating 20-29 30-39 40-49 50-59 20-29 30-39...
  • Page 13: Health Tips - About Body Fat

    The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Since we can’t judge body fat level simply by our weight, this body fat analyzer LS202-B1, –...
  • Page 14 Appendix Appendix Table 4 – Guidance and ’ declaration – electromagnetic – MANUFACTURER IMMUNITY Table 6 – Recommended separation distances between portable and mobile that are not ME EQUIPMENT ME SYSTEMS LIFE SUPPORTING RF communications equipment and the – ME EQUIPMENT ME SYSTEM that are not ME EQUIPMENT...