Process Sensors METIS M308 Quick Start Manual page 4

Pyrometers with 12-pin connector, display and push button device configuration

Advertisement

9
1. Connect the pyrometer:
2. Temperature display:
3. Digital inputs / outputs:
4. Set measuring parameters: - measuring relevant
5. Save measuring parameters: - save all values under a file name
6. Alignment:
(Icons device-dependent) - configure monitor settings of the camera module
7. Graphic presentation:
8. Record data:
9. Configuration Files:
10. Device configuration:
Process Sensors reserves the right to make changes in scope of technical progress or further developments.
PROCESS SENSORS CORPORATION
IR Temp. Sales Office: 787 Susquehanna Avenue, Franklin Lakes, NJ USA • Tel: 201-485-8773 • Fax: 201-485-8770
Corporate Headquarters: 113 Cedar Street, Milford, MA USA • Tel: 508-473-9901 • Fax: 508-473-0715
www.ProcessSensorsIR.com • irtemp@processsensors.com
8
7
- automatically (search)
- manually (select COM à connect)
- numerically (as on the pyrometer)
- graphically (displayed in time)
- shows active inputs or outputs
- rarely required
(
to extend)
- switching on / off laser targeting light
- set measuring distance at motorized focus
- customize view in the data recording window
- select view graphs
- save measurement data incl. all parameters
- customize recording settings
- show measurement information
- playback and analyze in the viewer
- save complete pyrometer configurations
(setups) and activate them on the PC or
externally via digital inputs
- perform basic device settings
- limit temperature range if necessary
- adapt analog outputs to terminals
- assign functions to digital inputs / outputs
- test analog and digital outputs
- access service functions
- configure interface and data collection settings
- adjusting the pyrometer to a specific measuring temperature value (single-point adjustment)
2
3
4
5
6
10
1
IN: digital inputs , OUT: digital outputs
Port
Parameters are read from pyrometer
Parameters of currently loaded file
Quickstart-Manual_M3_H3_RadiationPyrometers_12-pin
Measuring temperature
DT: read out device temperature
not activated,
inactive,
Select measurement parameters
or type in or via
quick adjustment (active field)
Save pyrometer parameters in file
Load parameters from file
Laser targeting light
Measuring distance at motorized focus
Monitor settings of camera module
Scale per mouse click
Scale per entry
Scale with mouse drag
Adapt to pyrometer's temp. range
Automatic scale (selected graphs)
(Feb 14, 2017)
A KPM Analytics Company
active

Advertisement

loading

This manual is also suitable for:

Metis m309Metis m316Metis m318Metis h309Metis h316Metis h318