Download Print this page
Flanders Scientific Inc. XM551U User Manual

Flanders Scientific Inc. XM551U User Manual

Hide thumbs Also See for XM551U:

Advertisement

Quick Links

Monitor User Manual
Updated 12.16.2021
XM551U
XM650U
XM651U
This manual is based on firmware version 2.1.20
Flanders Scientific, Inc.
6215 Shiloh Crossing
Suite G
Alpharetta, GA. 30005
Phone: +1.678.835.4934
Fax: +1.678.804.1882
E-Mail:
Support@FlandersScientific.com
www.FlandersScientific.com

Advertisement

loading

Summary of Contents for Flanders Scientific Inc. XM551U

  • Page 1 Monitor User Manual Updated 12.16.2021 XM551U XM650U XM651U This manual is based on firmware version 2.1.20 Flanders Scientific, Inc. 6215 Shiloh Crossing Suite G Alpharetta, GA. 30005 Phone: +1.678.835.4934 Fax: +1.678.804.1882 E-Mail: Support@FlandersScientific.com www.FlandersScientific.com...
  • Page 2 Contents TOPIC PAGE(S) Safety Precautions 3 - 5 Parts & Their Functions 6 - 7 Menu 8 - 18 Removing Pedestal Feet Dimensional Drawings Return to Table of Contents © 2021 Flanders Scientific, Inc.
  • Page 3 Safety Precautions OLED PANEL BURN-IN WARNING This display has been designed primarily for SDR Mastering / Monitoring applications. HDR monitoring modes are provided as well and may be useful for short term client review of HDR material. However, this display is not suggested for HDR mastering or long term HDR monitoring as prolonged use of these modes can reduce the lifespan of the display as well as have a negative impact on overall display performance.
  • Page 4 Safety Precautions Connecting and Disconnecting SDI BNC Cables To prevent damage to components from electrical discharge follow these steps: • Connect power first on all devices. • Power on all devices. • Connect BNC cables. To disconnect: • Disconnect BNC cables. •...
  • Page 5 Safety Precautions • If the product requires replacement parts, make sure that the service person uses replacement parts specified by the manufacturer, or those equivalent parts having the same characteristics and performance specifications as the original parts. Use of unauthorized parts can result in fire, electric shock, and/or other damage.
  • Page 6 Safety Precautions FCC (Federal Communications Commission) This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interface when the equipment is operated in a commercial environment.
  • Page 7 Parts & Their Functions Keyboard • SDI 1: Used to select SDI Input 1 as the active Input. • SDI 2: Used to select SDI Input 2 as the active Input. • SDI 3: Used to select SDI Input 3 as the active Input. •...
  • Page 8 Parts & Their Functions Back Panel • SDI In: 4 Multi-Format 12G/6G/3G/HD-SDI Inputs. • SDI Out: 4 Looped 12G/6G/3G/HD-SDI Outputs. • MON Out: Processed output. Follows Mode Selection. • DP In: Display Port Input. • Audio In/Out: Analog Stereo Mini-phono Au- dio Input &...
  • Page 9 Menu Navigating the Menu Pressing the MENU button on the monitor’s keypad will call up the on screen menu. To navigate use the UP and DOWN buttons and press the ENTER button to select the highlighted sub menu. Navigate the sub menu in the same way by using the UP and DOWN buttons to highlight a particular function and press ENTER to change that function’s settings.
  • Page 10 Menu - Function Menu Function Menu Function Luminance Scope Scope Vector Scope Video Pixel Mapping Color LUM Coloring System Area Marker Safety Marker Center Marker Load Profile 0 Load Profile 1 Load Profile 2 Load Profile 3 Load Profile 4 Load Profile 5 Load Profile Saved profile configurations can now be loaded via function button.
  • Page 11 Menu - Scope Menu Scope Menu Function Luminance Scope Lum Position Bottom Right Video Lum Style Color Vector System Vec Position Bottom Right Lum Coloring Lum & Vec Position Use Lum & Vec Position to select in what area of the screen you would like your Scopes to be displayed. Lum Style Select IRE or HDR (PQ) Waveform.
  • Page 12 Menu - Video Menu Video Menu Function Input SDI 1 Scope Mode AUTO Video SDI Format AUTO Color Pixel Mapping System Deinterlace Mode Mode 2 SDI Format Select the correct incoming signal format. SDI Format selection overrides payload ID if not set to AUTO. Mode The mode selection allows you to set the SDI input configuration as well as the processed monitor output configuration.
  • Page 13 Menu - Video Menu Video Menu Function Input SDI 1 Scope Mode AUTO Video SDI Format AUTO Color Pixel Mapping System Deinterlace Mode Mode 2 Pixel Mapping Pixel Mapping toggles between various available pixel mapping options including: With Pixel Mapping set to OFF the incoming source is scaled to fill as much of the screen as possible while preserving aspect ratio.
  • Page 14 Menu - Video Menu - Pixel Mapping Return to Table of Contents © 2021 Flanders Scientific, Inc.
  • Page 15 Gamma 2.4 Luminance Mode Luminance Custom ColorSystem Default - Default selection where XM551U, XM650U, and XM651U factory calibration LUTs are stored. GaiaColor - Reserved for future Use. LightSpace / CalMAN - Open slots for use with LightSpace and CalMAN. LUT Mode Does not apply to GaiaColor Color System.
  • Page 16 Menu - Color Menu Color Menu Function ColorSystem User Scope LUT Mode Normal Video Range SMPTE Full 4-1019 Color Gamut BT.709 System Temperature Default EOTF Gamma 2.4 Luminance Mode Luminance Custom Gamut Select from available options to instantly change the active color space. This will enable both the 3D Calibration LUT and Post 1D Calibration LUT positions stored to the corresponding memory bank.
  • Page 17 This setting deletes the Factory AWB calibration. Do not use this setting unless you have the proper equipment to redo the factory AWB calibration. Basic settings for the most commonly used configuration on the XM551U, XM650U, and XM651U are provided below: For Rec709 2.4 SDR...
  • Page 18 Menu - System Menu System Menu Function Update Firmware Allow Scope Current IP 192.168.1.100 Video Version 2.1.20 Color Serial Number XM310A0000 System Payload ID 0000 Profile Load Profile Save Set Static IP 192.168.1.100 192.168.1.100 IP Reset DHCP 255.255.255.0 Clear Panel Noise 192.168.1.1 Panel Dimming Apply Settings...
  • Page 19 Menu - System Menu System Menu Function Update Firmware Allow Scope Current IP 192.168.1.100 Video Version 2.1.20 Color Serial Number XM310A0000 System Payload ID 0000 Profile Load Profile Save Set Static IP 192.168.1.100 192.168.1.100 IP Reset DHCP 255.255.255.0 Clear Panel Noise 192.168.1.1 Panel Dimming Apply Settings...
  • Page 20 Menu - OSD Menu OSD Menu Function Time Code Scope Status Position Top Left Video Status Set Color Menu Position Top Left System Menu Set Area Marker Safety Marker Center Marker Time Code Allows you to select whether to display Time Code on screen pulled from an SDI signal. Reserved for future use, inactive in 1.1.75 Menu &...
  • Page 21 Removing Pedestal Feet XM551U, XM650U, and XM651U have pedestal style feet that can be removed when wall mounting. The feet are held on by six screws per foot on the bottom. Return to Table of Contents © 2021 Flanders Scientific, Inc.
  • Page 22 Dimensional Drawing - XM551U Large Dimensional Drawing PDF available online. http://www.flandersscientific.com/uploads/XM551Udim.pdf Return to Table of Contents © 2021 Flanders Scientific, Inc.
  • Page 23 Dimensional Drawing - XM650U Large Dimensional Drawing PDF available online. http://www.flandersscientific.com/uploads/XM650Udim.pdf Return to Table of Contents © 2021 Flanders Scientific, Inc.
  • Page 24 Dimensional Drawing - XM651U Large Dimensional Drawing PDF available online. http://www.flandersscientific.com/uploads/XM651Udim.pdf Return to Table of Contents © 2021 Flanders Scientific, Inc.