<Main menu list of PAR-31MAA>
Setting and display items
Vane · Louver · Vent.
(Lossnay)
High power
Timer
On/Off timer*
Auto-Off timer Use to set the Auto-Off time.
Filter information
Error information
Weekly timer*
Energy
Auto return
saving
Schedule*
Night setback*
Restriction
Temp. range
Operation
lock
Maintenance
Auto descending
panel
Manual vane
angle
Initial setting
Main/Sub
Clock
Main display
Contrast
* Clock setting is required.
OCH670
Use to set the vane angle.
• Select a desired vane setting from five different settings.
Use to turn ON / OFF the louver.
• Select a desired setting from "ON" and "OFF."
Use to set the amount of ventilation.
• Select a desired setting from "Off," "Low," and "High."
Use to reach the comfortable room temperature quickly.
• Units can be operated in the High-power mode for up to 30 minutes.
Use to set the operation On/Off times.
• Time can be set in 5-minute increments.
• Time can be set to a value from 30 to 240 in 10-minute increments.
Use to check the filter status.
• The filter sign can be reset.
Use to check error information when an error occurs.
• Check code, error source, refrigerant address, unit model, manufacturing number, contact
information (dealer's phone number) can be displayed.
( The unit model, manufacturing number, and contact information need to be registered in
advance to be displayed.)
Use to set the weekly operation On / Off times.
• Up to eight operation patterns can be set for each day.
(Not valid when the On/Off timer is enabled.)
Use to get the units to operate at the preset temperature after performing energy-save
operation for a specified time period.
• Time can be set to a value from 30 and 120 in 10-minute increments.
(This function will not be valid when the preset temperature ranges are restricted.)
Set the start/stop times to operate the units in the energy-save mode for each day of the week,
and set the energy-saving rate.
• Up to four energy-save operation patterns can be set for each day.
• Time can be set in 5-minute increments.
• Energy-saving rate can be set to a value from 0% and 50 to 90% in 10% increments.
Use to make Night setback settings.
• Select "Yes" to enable the setting, and "No" to disable the setting. The temperature range and
the start/stop times can be set.
Use to restrict the preset temperature range.
• Different temperature ranges can be set for different operation modes.
Use to lock selected functions.
• The locked functions cannot be operated.
Auto descending panel (Optional parts) Up / Down you can do.
Use to set the vane angle for each vane to a fixed position.
When connecting two remote controllers, one of them needs to be designated as a sub
controller.
Use to set the current time.
Use to switch between "Full" and "Basic" modes for the Main display.
• The initial setting is "Full."
Use to adjust screen contrast.