Q:Is there port cannot be set to port trunking for DES-3224 and DES-5024?
Yes, there are some port in the switch cannot be set to port trunking.
For DES-5024, port 5/6/7/8 and port 17/18/19/20 are not the first ports of the PSP, these ports cannot be selected as part
of the trunk group.
For DES-3224, port 3/4, 11/12, 15/16 and 23/24 cannot be selected as part of the trunk group.
Q:Is there any limitation for setting port trunking in DES-1016?
Yes, DES-1016 totally support four trunk groups, it ONLY allow user to set 4 port as a trunk group.
Reference
1. IBM Ethernet Workgroup Switch Raven/Cardinal(DES-5024,DES-3224) Software
Functional Specification. Draft v1.02
2. D-Link DES-1016 Software Internal specification