Expansion enclosure
Table of Contents

Advertisement

a. Align the right rail with the lower two U spaces of the 4U mounting location.
b. With the release latch on the outer part of the rack post, place the catch mechanism over the post.
c. Push the rail back to secure the rail to the rack post.
An audible click indicates that the rail is secure in the post.
d. Make sure the post/catch mechanism is secure and attached to the rack post.
Figure 5. Attach Rail to the Back of the Rack
3.
Attach the right rail to the front post of the rack.
a. Align the right rail with the lower two U spaces of the 4U mounting location.
b. Pull the rail forward, with the alignment pins in the middle holes of the bottom two U spaces of the 4U mounting location.
An audible click indicates that the rail is secure in the post.
Figure 6. Attach Rail to the Front of the Rack
4.
Secure the rail by installing an M5 x 10 mm screw (106-002-452) in the larger of the two holes at the front of the rail.
5.
Secure the rail by installing an M5 x 16 mm screw (106-002-453) in the larger of the two holes at the back of the rail.
6.
Repeat steps 2 through 5 to install the left rail.
7.
Mount the expansion enclosure chassis on the rails.
a. If a mechanical lift is available, use the four handles that shipped with the expansion enclosure to lift the expansion
enclosure chassis onto a mechanical lift.
b. If a mechanical lift is not available, remove the drives, cooling fans, power supply units (PSUs), and enclosure management
modules (EMMs) from the expansion enclosure chassis and use the four handles to lift the chassis to the mounting location.
c. From the front of the rack, extend the rack rails approximately 5 to 8 cm (2 to 3 in.) and align the expansion enclosure
chassis rails with the rack rails.