9.6. Vibration Strength (in individual packing)
There shall be no sign of malfunction after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10Hz to 100Hz at an accelerated
2
velocity of 19.6 m/s
(2.0 G) for 30 minutes (60 minutes per cycle) in individually packaged state.
Repeat this in each X, Y and Z direction.
9.7. Drop Impact Strength (without packaging)
There shall be no sign of malfunction after the following drop test.
Drop test: Drop the scanner 30 times in total (5 times at each 6 face) from a height of 150 cm onto
a concrete floor as shown below.
9.8. Drop Impact Strength (in individual packaging)
There shall be no sign of malfunction after the following drop test.
Drop test: Drop an individually packaged scanner 10 times in total, at any of 1 corner, 3 edges, and
6 faces, from a height of 150 cm onto a concrete floor.
9.9. Electrostatic Discharge (ESD) Immunity
Contact discharge
Aerial discharge
Measurement environment
Discharge resistance
Charging capacitor
Concret
Figure 10: Drop Test
: ±6 kV max (direct or indirect discharge, no malfunction)
: ±8 kV max (no malfunction)
±15 kV max (no distraction)
: Testing method compliant with IEC-61000-4-2.
: 330 Ω
: 150 pF
17
OPN-3200i
Specifications Manual
150cm
150 cm