7.2. Aiming Pattern
The aiming is used for the following purpose:
1. Light source to indicate the appropriate reading range
2. Light source for auto trigger operation
The aiming specifications are as follows:
・ An optical axis of imaging field of view and the center of horizontal aiming width coincide at a
distance of L=65±20 mm from the front edge of the scanner.
・ The horizontal aiming width to the horizontal width of imaging filed of view at a distance of L=65
mm is 80%±10%.
7.3. Imaging Range
The range is ±5% from the following values.
L: Distance from the front edge of scanner
H: Horizontal imaging range
V: Vertical imaging range
Figure 2: Aiming Pattern and Imaging Range
[mm]
60
[mm]
66
[mm]
42
8
Specifications Manual
80
100
120
140
82
97
111
125
52
62
72
82
OPN-3200i
160
136
93