Table Of Contents; Safety Pracecautions - Daikin AVA125AMVE Operation Manual

System
Hide thumbs Also See for AVA125AMVE:
Table of Contents

Advertisement

CONTENTS
ILLUSTRATION ............................................. 1
1. SAFETY PRACECAUTIONS ......................... 2
3. OPERATION RANGE .................................... 6
4. INSTALLATION SITE .................................... 6
5. OPERATION PROCEDURE .......................... 7
7. OPTIMUM OPERATION .............................. 10
(FOR SERVICE PERSONNEL) ................... 10
CONDITIONER ............................................ 12
10. TROUBLE SHOOTING ................................ 14
11. DISPOSAL REQUIREMENTS ..................... 16
Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using
the air conditioner. It will tell you how to use the unit
properly and help you if any trouble occurs. After
reading the manual, file it away for future reference.
Furthermore, make certain that this operation man-
ual is handed to a new user when he takes over the
operation.
The original instructions are written in English.
All other languages are translations of the original
instructions.
This operation manual is dedicated for the indoor
unit. Also refer to the operation manuals provided
with the outdoor unit and remote controller.
Important information regarding the
refrigerant used
This product contains fluorinated greenhouse gases.
Do not vent gases into the atmosphere.
Refrigerant type:
R32
(1)
GWP
value:
675
Refrigerant type:
R410A
GWP
(1)
value:
2087.5
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be
required depending on European or local legislation.
Please contact your local dealer for more information.
NOTICE regarding tCO
In Europe, the greenhouse gas emissions of the
total refrigerant charge in the system (expressed as
tonnes CO
-equivalent) is used to determine the
2
maintenance intervals. Follow the applicable
legislation.
Formula to calculate the greenhouse gas
emissions:
GWP value of the refrigerant × Total refrigerant
charge [in kg] / 1000
English
eq
2

1. SAFETY PRACECAUTIONS

To gain full advantage of the air conditioner's functions and to
avoid malfunction due to mishandling, please read this opera-
tion manual carefully before use.
This appliance is intended to be used by expert or
trained users in shops, in light industry and on farms,
or for commercial use by lay persons.
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user
maintenance shall only be done by persons described
in manual.
The appliance is not intended for use by unattended
young children or persons who are incompetent to
operate air conditioners.
It may result in injury or electric shocks.
This manual classifies the precautions into WARNINGS
and CAUTIONS. Be sure to follow all the precautions
below: They are all important for ensuring safety.
WARNING ....... Indicates a potentially hazardous situation
which, if not avoided, could result in death
or serious injury.
CAUTION ........ Indicates a potentially hazardous situation
which, if not avoided, may result in minor
or moderate injury.
It may also be used to alert against unsafe
practices.
After reading, keep this manual in a convenient place so
that you can refer to it whenever necessary. If the equip-
ment is transferred to a new user, be sure also to hand
over the manual.
WARNING
When the air conditioner is malfunctioning (giving off a
burning odor, etc.), turn off the power to the air condi-
tioner and contact your local dealer.
Continued operation under such circumstances may result
in a failure, electric shocks or a fire.
Consult your local dealer regarding modification,
repair and maintenance of the air conditioner.
Improper workmanship may result in water leakage, electric
shocks or a fire.
Be sure to use fuses with the correct ampere reading.
Do not use improper fuses, copper or other wiring as a sub-
stitute, as this may result in electric shocks, a fire, injury or
damage to the air conditioner.
Consult your local dealer if the air conditioner sub-
merges owing to a natural disaster, such as a flood or
typhoon.
Do not operate the air conditioner in that case, or otherwise
a malfunction, electric shocks, or a fire may result.
2

Advertisement

Table of Contents
loading

Table of Contents