SUPREME FUSION 18 Owner's Manual

SUPREME FUSION 18 Owner's Manual

Hide thumbs Also See for FUSION 18:

Advertisement

Quick Links

FUSION 18
FIREPLACE INSERT, MODEL
«
»
Tested and listed to ULC S628 and UL 1482 by an accredited lab.
This unit is certified to comply with Phase II particulate emission standards from the
Environmental Protection Agency.
OWNER'S MANUAL
- INSTALLATION
- OPERATION
Important : Keep the owner's manual for future use
This product is proudly manufactured in North America by:
3594 Jarry East
Montreal, QC, H1Z 2G4
Tel: (514) 593-4722 Fax: (514) 593-4424
www.supremem.com
th
Revised: August 16
, 2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FUSION 18 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SUPREME FUSION 18

  • Page 1 FUSION 18 FIREPLACE INSERT, MODEL « » Tested and listed to ULC S628 and UL 1482 by an accredited lab. This unit is certified to comply with Phase II particulate emission standards from the Environmental Protection Agency. OWNER’S MANUAL - INSTALLATION - OPERATION Important : Keep the owner’s manual for future use...
  • Page 2: Table Of Contents

    Table of Contents 1   SAFETY ................................ 4   2   COMPONENTS ............................. 5   2.1   Overall Dimensions ..........................5   2.2   Specifications ............................6   2.3   Combustion Air Control .......................... 6   2.4   Cold Hand Key ............................7   2.5  ...
  • Page 3 4.1   Fuel ..............................15   4.2   First Fires ............................. 15   4.3   Operating the Combustion Air Control ....................15   4.4   Starting a Fire ............................16   4.5   Adding a New Load of Wood ....................... 17   4.6  ...
  • Page 4: Safety

    1 SAFETY SUPREME FIREPLACES INC. congratulates you on purchasing a FUSION 18 wood burning fireplace insert. This insert complies with the ULC S628 and UL 1482 standards. In addition, this wood insert is certified to comply with Phase II particulate emission standards from the US Environmental Protection Agency.
  • Page 5: Components

    2 COMPONENTS 2.1 Overall Dimensions Figure 1: FUSION 18 Firebox Figure 2: Dimensions of FUSION 18 Firebox Figure 3: Dimensions of FUSION 18 Figure 4: Dimensions of FUSION 18 with Circulating Chamber...
  • Page 6: Specifications

    It is located on the top of the firebox, at the front center of the unit (see Figure 5). The combustion air control of the FUSION 18 has two components: the Activator and the Burn Rate Selector.
  • Page 7: Cold Hand Key

    85°F. The speed of the fans can be adjusted with the variable speed control mounted on the wall. It is safe to operate the FUSION 18 in the event of a power failure...
  • Page 8: Surround

    The FUSION 18 wood burning insert is available in three different sizes. Figure 9: Surround Size Options - Small, Medium, and Large (Left to Right) NOTE: SUPREME FIREPLACES INC. reserves the right to alter the dimensions of the surrounds without prior notice.
  • Page 9: Serial Number

    The Metal Tag reads as follows: This fireplace has been altered to accommodate a fireplace insert and should be inspected by a qualified person prior to re-use as a conventional fireplace. Ce foyer a été modifié afin d'y insérer un foyer encastrable et doit être inspecté par une personne qualifiée avant sa réutilisation comme foyer conventionnel.
  • Page 10: Installation Instructions

    The masonry fireplace is to be constructed in accordance to N.F.P.A. 211 (Latest Edition), Standards of Chimney, Fireplaces, Vents and Solid-Fuel-Burning Appliances and Equipment. The FUSION 18 fireplace insert is intended only for masonry fireplaces installed with a continuous chimney liner of 5 inch diameter extending from the fireplace insert to the top of the chimney.
  • Page 11: Preparing The Firebox For Installation

    3.1 Preparing the Firebox for Installation a) Remove the door by opening it, lifting it, and pulling it towards the bottom until the rod exits from the hinge holes. b) Install the adjustable legs (see Section 2.10). The adjustable legs must extend 1 ¼ inch from the bottom of the firebox.
  • Page 12: Liner Adaptor Installation

    3.6 Power Cord Side Reversal The blowers of the FUSION 18 insert are factory installed and the power cord is located at the left side of the surround when facing it (refer to Figure 18). However, the power cord location...
  • Page 13: Surround Installation

    • A permanent warning label in metal must be fastened inside the firebox of the factory built fireplace stating that the fireplace can only be used with the FUSION 18 insert unless it has been restored to its original condition.
  • Page 14: Clearances To Combustibles

    Table 3: Depth of Mantle with Respect to Distance of Base Distance from the Base of Maximum The depth of the mantle is measured from the face of the the FUSION 18 to the Bottom Mantle Depth fireplace door. When the non-combustible wall is recessed, of the Mantle the depth of the mantle can be increased by the amount of the recess.
  • Page 15: Operation Instructions

    Due to oil residues and the curing of the paint of the fireplace, it is normal to smell an odor for the first fires of the FUSION 18. Open a window or a door near the fireplace insert to ventilate the house during the first fires.
  • Page 16: Starting A Fire

    WARNING: Never manipulate the Combustion Air Control with bare hands as it gets hot when the FUSION 18 is in operation. Use the Cold Hand Key to adjust the Combustion Air Control. WARNING: This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.
  • Page 17: Adding A New Load Of Wood

    Once the embers begin to glow red, add the new load of wood in the firebox. e) Keep the door of the FUSION 18 slightly unlatched until you see a flame in the firebox. Never leave the FUSION 18 door unlatched without constant supervision.
  • Page 18: Barbecue Grill

    Foods that are commonly grilled in a conventional barbecue can be cooked in the FUSION 18 insert. The intense heat from the next combustion cycle cleans the grill and the unit of any cooking residue.
  • Page 19: Troubleshooting

    Draft is the force created by a difference in pressure, which moves air from the appliance up through the chimney. It is important to operate the FUSION 18 with proper draft to ensure optimal performance of the unit. Draft is depended on the length of the chimney, local geography, nearby obstructions and other factors. Proper draft results in an upwards flow through chimney, which prevents smoke infiltrating into the house during operation of the unit.
  • Page 20: Maintenance

    (if needed) by a qualified technician. NOTE: Do not clean the chimney when the unit is in operation/hot. Follow the instructions below for sweeping the chimney of a FUSION 18 fireplace insert: a) Open the door of the unit.
  • Page 21: Cleaning Of Glass

    6.5 Replacement of Glass SUPREME FIREPLACES INC. uses a high quality 5mm thick Pyroceram III / Keralite ceramic glass that can withstand temperatures up to 1300 F. It is recommended to perform a weekly visual check for any damages or cracks on the glass.
  • Page 22: Door Latch Lubrication

    d) Using a wedging tool or flat head screwdriver, gently remove the ¾” gasket (along with the silicone) from the door framing. e) Using a wrench, remove the 8 nuts fastened around the door framing. Remove the first row of metal brackets (2 small and 2 big) and thin gasket. g) Remove the damage glass and clean thoroughly the door framing from loose glass fragments.
  • Page 23: Replacement Parts

    6.9 Replacement Parts Refer to the codes from the table below for any replacement parts: Code Description Illustration Wood pull handle (specify color) Pyroceram III / Keralite 5mm thick glass, PYRO_20.25X12 20.25" X 12" Graphite coated square gasket, 0.1875" GSK_19_6 thick, 6' length Graphite coated square gasket, 0.25"...
  • Page 24: Warranty

    EXCLUSIONS: SUPREME FIREPLACES INC. shall not be responsible for any labor costs for the replacement or repair of any electrical components, painted/plated parts, secondary air burning system, and the combustion air control. The following parts are guaranteed for 1 year: blowers, painted/plated parts, secondary air burning system, soapstone, and door gasket.
  • Page 25 In the case of a return for repair or replacement, it is the responsibility of the customer to adequately package the component/unit to prevent further damage during transport. Items sent to the SUPREME FIREPLACES INC. without an open warranty claim will be returned to the sender. Warranty claims should be addressed to: SUPREME FIREPLACES INC.

Table of Contents