Marq Gesture Beam 400 User Manual page 6

Hide thumbs Also See for Gesture Beam 400:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Follow these steps to use a safety cable (not
1
2
3
included) to secure the fixture to a truss. We
recommend using a safety cable with a
diameter of at least 5 mm and a load
capacity of at least 272 lbs. (124 kg).
Linking
When using multiple Gesture Beam 400 fixtures, you can link ("daisy-chain") them so that each each fixture
supplies power and/or sends DMX data to the next one. This helps reduce clutter in your cabling and save
you setup time.
You do not have to link fixtures for both power and DMX control; you can link them for either purpose
independently. For instance, you could link 8 fixtures together for DMX control while linking only 4 of those
same fixtures together for power (powering the other 4 fixtures separately).
Power
Use a standard IEC power cable to connect the Power Out of one fixture to the Power In of another. As
long as the first fixture is connected to a power outlet, any of the linked fixtures can remain off and still
supply power to the next one.
Important: To prevent undue damage to your fuses, we recommend linking no more than 6 fixtures in the
same chain.
Power
Gesture Beam 400
Gesture Beam 400
Gesture Beam 400
DMX
Use a standard 3-pin DMX cable to connect the DMX Out of one fixture to the DMX In of another. Your
connected DMX controller will send its data to the fixtures in sequence. All fixtures in this chain will receive
all DMX data.
DMX Controller
Gesture Beam 400
Gesture Beam 400
Gesture Beam 400
6

Advertisement

Table of Contents
loading

Table of Contents