C98(43 39 38 0D)
C99(43 39 39 0D)
C51(43 35 31 0D)
C52(43 35 32 0D)
C53(43 35 33 0D)
C54(43 35 34 0D)
C55(43 35 35 0D)
C56(43 35 36 0D)
C57(43 35 37 0D)
CR0(43 52 30 0D) #
CR1(43 52 31 0D)
CR2(43 52 32 0D) #
CR3(43 52 33 0D) #
CR9(43 52 39 0D) #
CRA(43 52 41 0D) #
CLN(43 4C 4E 0D)#
CLF(43 4C 46 0D)#
KEYSTONE+
KEYSTONE-
USB
USB-UP
USB-DOWN
USB-LEFT
USB_RIGHT
USB-ENTER
USB-ESC
POWER-STATUS
SOURCE-STATUS
LAMP
TIMER-STATUS
FILTER
TIMER-STATUS
SYSTEM ERROR
CODE
SYSTEM ERROR
CODE (10 last
codes)
Set LAN POWER
ON
Set LAN POWER
OFF
For USB source only
For USB source only
For USB source only
For USB source only
For USB source only
For USB source only
STATUS feedback
"000" - projector is on
"800" - projector is standby
"200" - projector is cooling down
"500"- Projector is warming up
STATUS feedback
"001" – COMPUTER1
"002" – DVI
"003" – COMPUTER2
"010" - VIDEO
"020" - S-VIDEO
"004" - YPbPr
STATUS feedback
"X,XXX,XXX Mins"– Lamp usage
timer in minutes
STATUS feedback
"X,XXX,XXX Mins"– Filter usage
timer in minutes
A: Lamp temperature switch fail
B: Lamp cover switch fail
C: Lamp/Ballast fail
D: Fan: Exhaust fan fail
E: Fan: Lamp blower fail
F: Fan: Image blower fail
G: Inlet temp sensor fail
H: Image Temp sensor fail
I: Lamp Temp sensor fail
J: Over temp: Inlet Temp sensor
K: Over temp: Image Temp sensor*
L: Over temp: Lamp Temp sensor
M: Blank feature time out
N: No Signal time out
I,X,XXX,XXX,XXX
I will be 0 to 9 to indicate the index
position of upcoming error code.