5.4. HDCP SETTING
- HDCP setting is not necessary in Saturn5 model.
5.5 Option selection per country
(1) Overview
- Option selection is only done for models in Non-USA
North America due to rating
- Applied model: LA92A Chassis applied None USA
model(CANADA, MEXICO)
(2) Method
1) Press ADJ key on the Adj. R/C, then select Country
Group Menu
2) Depending on destination, select KR or US, then on the
lower Country option, select US, CA, MX. Selection is
done using +, - KEY
5.6. Tool Option selection
• Method: Press Adj. key on the Adj. R/C, then select Tool
option.
Model
Tool 1 Tool 2 Tool 3 Tool 4 Menu
19LD350(CMO)
19LD350(LGD)
2689
22LD350(CMO)
22LD350(LGD)
6785
26LD350(Sharp)
26LD350(AUO)
10897 1576
32LD350(AUO)
19089 1576
5.7. Ship-out mode check (In-stop)
• After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode.
• After final inspection, Always turn on the Mechanical S/W.
Copyright
LG Electronics. Inc. All right reserved.
Only for training and service purposes
1 HDMI
548
1442
1824
1 HDMI
1HDMI
548
1442
1824
1 HDMI
2HDMI
1442
1824
2 HDMI
34210 1824
2 HDMI
6. GND and Internal Pressure check
6.1. Method
1) GND & Internal Pressure auto-check preparation
- Check that Power Cord is fully inserted to the SET.
(If loose, re-insert)
2) Perform GND & Internal Pressure auto-check
- Unit fully inserted Power cord, Antenna cable and A/V
arrive to the auto-check process.
- Connect D-terminal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator.
- If OK, changeover to I/P check automatically.
(Remove CORD, A/V form AV JACK BOX)
- Perform I/P test
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow the
pallet to move on to next process.
6.2. Checkpoint
• TEST voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
• TEST time: 1 second
• TEST POINT
- GND TEST = POWER CORD GND & SIGNAL CABLE
METAL GND
- Internal Pressure TEST = POWER CORD GND & LIVE &
NEUTRAL
• LEAKAGE CURRENT: At 0.5mArms
- 14 -