Baxi 100/2 HE Plus Installation & Servicing Instructions Manual page 18

Wall mounted powered flue condensing boiler, gas fired central heating unit
Table of Contents

Advertisement

Fig. 18
0.5m
Pictorial examples of flue runs where EQUIVALENT flue length equals 4m
18
1m
0.5m
Fig. 19
7.0 Site Requirements
7.8
See Section 2.2. The standard horizontal flue kit allows
for flue lengths between 270mm (10
(32") from elbow to terminal (Fig. 18).
The maximum permissible equivalent flue length is: 4
metres (Fig. 18a).
NOTE: Each additional 45° of flue bend will
account for an equivalent flue length of 0.5m.
eg. 45° = 0.5m,
7.9
1. When codes of practice dictate the use of terminal
guards, they can be obtained from most Plumbers' and
Builders' Merchants.
2. When ordering a terminal guard, quote the appliance
model number.
3. The flue terminal guard should be positioned
centrally over the terminal and fixed as illustrated.
0.5m
7.10
Fig. 18a
1. Only a flue approved with the Baxi 100/2 HE Plus
can be used.
2. For information on vertical flues consult the Baxi Flue
Guide Brochure or Notes for Guidance supplied with
the vertical flue pack.
Flue Dimensions
5
/
") and 800mm
8
90° = 2 x 45° = 1m etc.
Terminal Guard (Fig. 19)
Vertical Flue

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents