8 AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
At Idle
1/8th Power Pink Noise
Typical of program material
just at clip.
1/3rd Power Pink Noise
Typical of program material
with severe clipping.
page 28
Rated
Line Current
Load
Power
8 Ohms/Ch.
600x2
16 Ohms Bridge
1200
4 Ohms/Ch.
600x2
8 Ohms Bridge
1200
2 Ohms/Ch.
250x2
4 Ohms Bridge
500
100V/Ch.
600x2
140/200V Bridge 1200
8 Ohms/Ch.
600x2
16 Ohms Bridge
1200
4 Ohms/Ch.
600x2
8 Ohms Bridge
1200
2 Ohms/Ch.
250x2
4 Ohms Bridge
500
70V/Ch.
600x2
140/200V Bridge 1200
CTs 1200
Line Current
120VAC
230VAC
watts in
60
7.6
3.8
641
10.0
5.0
872
8.8
4.4
1330
7.6
3.8
641
11.5
5.7
996
15.5
7.8
1372
13.4
6.7
1217
11.5
5.7
996
CTs Power Amplifi ers
Watts
Thermal Dissipation
watts out
dissapated
Btu/hr
0
60
205
157
484
1651
151
720
2458
405
925
3158
157
484
1651
403
593
2025
405
967
3300
168
1050
3582
403
593
2025
Operation Manual
kcal/hr
52
416
620
796
416
511
832
903
511