6 Troubleshooting
page 22
CONDITION: No sound, even though
the amp has power. Power LED is on
with out fl ashing and the amp is receiving an input
sig nal. Signal indicator is fl ashing.
POSSIBLE REASON:
Speakers not connected.
Open circuit due to speaker failure.
There is a short on the amplifi er output. First
disconnect your speakers from the affected
channel(s) one by one to determine if one of
the loads is shorted.
Ready LED is off. Channel has been set to
standby mode via the control system.
CONDITION: No input signal. Signal
indicator is not fl ashing even though audio is
applied, and the channel is ready..
POSSIBLE REASON:
Input signal level is very low.
Level controls are turned down.
CTs Power Amplifi ers
CONDITION: Data indicator not
fl ash ing, even though PIP module is
installed and host computer control
software is active.
POSSIBLE REASON:
Cable between computer and PIP module is
broken or not connected.
Note: Data indicator fl ashes only when the installed
PIP2 module is polled for data, or is polled to see
whether it is online.
CONDITION: Bridge LED is lit.
POSSIBLE REASON:
Amplifi er is in bridge-mono mode.
"Off/Flashing/On" above means that
the LED can be off, or fl ashing, or on.