Toshiba RAS-07EKV-EE Service Manual page 22

Indoor unit outdoor unit
Table of Contents

Advertisement

7-2. Operation Data
<Cooling>
<Cooling>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
07EKV-EE
27/19
35/-
10EKV-EE
13EKV-EE
<Heating>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
20/-
7/6
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m
Standard
pressure
P (MPa)
0.9 to 1.1
0.9 to 1.1
0.8 to 1.0
Standard
pressure
P (MPa)
07EKV-EE
2.4 to 2.6
10EKV-EE
2.4 to 2.6
13EKV-EE
2.6 to 2.8
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
9 to 11
47 to 49
9 to 11
47 to 49
11 to 13
46 to 48
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
43 to 45
0 to 3
0 to 3
43 to 45
41 to 43
0 to 2
– 21 –
FILE NO. SVM-13029
Indoor
Outdoor
fan mode
fan mode
High
High
High
High
High
High
Indoor
Outdoor
fan mode
fan mode
High
High
High
High
High
High
Compressor
revolution
(rps)
50
73
94
Compressor
revolution
(rps)
60
94
94

Hide quick links:

Advertisement

Table of Contents
loading