Advertisement

Quick Links

REMOTE KEYLESS ENTRY SYSTEMS
INSTALLATION & OPERATING INSTRUCTIONS
CS-845RKE Series II / CS-855RKE
CONGRATULATIONS on your choice of a Remote Keyless Entry System by Crimestopper Security Products
Inc. This booklet contains the information necessary for installing, and using your system. If any questions
arise, contact your installation dealer or Crimestopper Security Products Inc. at the Tech Support number
below.
*IMPORTANT INFORMATION: Primary and Optional Features
-PRIMARY: These are features that must be connected in order for the system to operate properly i.e. Power,
Ground, Lights, Power Locks, etc.
-OPTIONAL: Optional features are connected only if desired or agreed upon by the installing dealer i.e. Horn
Honk, Dome light illumination, Starter Kill, L.E.D., Trunk Pop, etc. These features may require additional parts
and labor charges. Consult with your installer about these features before installation.
TECH SUPPORT
Mon-Fri 8:00 AM-4:30 PM Pacific Time
(800) 998-6880
www.crimestopper.com
email@crimestopper.com
REV. C 12.2002
INTRODUCTION
This device complies with FCC Rules part 15. Operation is subject to the
following two conditions: 1) This device may not cause interference, and (2)
this device must accept any interference that may be received, including
interference that may cause undesired operation. The manufacturer is not
responsible for any radio or TV interference caused by unauthorized
modification to this equipment. Such modification could void the user's
authority to operate the equipment.
Update:
CS-845RKE Series II, new wire
harness CS-845RKE.
New 845RKE wire colors.
Option #7 Extended Horn Chirp

Advertisement

loading
Need help?

Need help?

Do you have a question about the CS-845.RKE.II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CrimeStopper CS-845.RKE.II

  • Page 1 CONGRATULATIONS on your choice of a Remote Keyless Entry System by Crimestopper Security Products Inc. This booklet contains the information necessary for installing, and using your system. If any questions arise, contact your installation dealer or Crimestopper Security Products Inc. at the Tech Support number below.
  • Page 2: Installation Cautions & Warnings

    INSTALLATION CAUTIONS & WARNINGS BEFORE BEGINNING, check all vehicle manufacturer cautions and warnings regarding electrical service (AIR BAGS, ABS BRAKES, AND BATTERY). DO NOT ROUTE ANY WIRING THAT MAY BECOME ENTANGLED with brake, and gas pedals, steering column, or any other moving parts in the vehicle. REMOVE MAIN SYSTEM FUSE(S) before jump starting the vehicle or charging the battery at high boost.
  • Page 3 GRAY WIRE: (-) AUXILIARY REMOTE OUTPUT 1 (Optional, requires relay) Connect to terminal 85 of relay. Connect terminal 86 to constant. Connect terminal 87 to +12V or Ground depending on the type of circuit that needs to activated. Connect terminal 30 to the device/circuit to be activated. Controlled by pressing and holding Button (3) Trunk Pop for more than 1 second.
  • Page 4 CS-845 RKE POWER DOOR LOCK WIRING 3 PIN (WHITE): DOOR LOCK OUTPUT PLUG GREEN: (-) Negative LOCK pulse RED: +12V Coil Power for external relays (Term. 86). BLUE: (-) Negative UNLOCK pulse CS-845RKE NEGATIVE TRIGGER DOORLOCK WIRING GREEN BLUE CS-845RKE REV. POLARITY DOOR LOCK WIRING GREEN BLUE MASTER...
  • Page 5 CS-855 RKE POWER DOOR LOCK WIRING 3 PIN (WHITE): DOOR LOCK OUTPUT PLUG GREEN: (-) Negative LOCK pulse / (+) Positive UNLOCK pulse RED: +12V Coil Power for external relays (Term. 86). BLUE: (-) Negative UNLOCK pulse / (+) Positive LOCK pulse CS-855 RKE NEGATIVE TRIGGER DOORLOCK WIRING GREEN BLUE...
  • Page 6 CS-845/855 SEPARATE DRIVER’S DOOR UNLOCK DIAGRAMS REVERSE POLARITY DOOR LOCKS VIOLET (BLUE/WHITE 845) GREEN BLUE DRIVER'S DOOR MOTOR 30 87A UNLOCK WIRE NEGATIVE TRIGGER DOOR LOCKS VIOLET (BLUE/WHITE 845) GREEN BLUE DRIVER'S DOOR MOTOR UNLOCK WIRE FACTORY LOCK RELAYS +12V FUSED FUSED +12V...
  • Page 7: Option Programming

    CS-855RKE TRANSMITTER PROGRAMMING 1. Turn Ignition ON and OFF 3 times quickly, leaving it ON the 3 flash once and one horn chirp if horn chirp feature is installed. 2. Push and hold the Program/Override Button for 5 seconds until you hear 3 horn chirps and lights flash 3 times. 3.
  • Page 8 PROGRAMMING OPTIONS CHART Option # Option Description Auto Lock & Unlock with Ignition ON or OFF Double Unlock Pulse Horn Chirp Lock/Unlock Pulse Time Passive Starter Disable Ignition Trigger Extended Horn Chirp 1. AUTOLOCK / UNLOCK WITH IGNITION Controls whether the doors will automatically lock when the ignition is turned on and will unlock when the ignition is turned off.
  • Page 9: Operation

    OPTION PROGRAMMING cont. 7. EXTENDED HORN CHIRP This option allows the unit to provide a slightly longer lock/unlock horn chirp output. This option is ONLY required on specific vehicles where the normal horn chirp is not long enough to activate the factory horn and produce a chirp. OPTION RESET PROCEDURE: Programmable Options can be instantly restored to Factory Default Values (*): To restore default values, perform step #1 on page 8, then just press button #3 (Trunk) on the remote.
  • Page 10 IGNITION TRIGGER (OPTIONAL) This optional feature allows the unit to activate the panic mode if an unauthorized operator turns on the Ignition after the vehicle had been locked using the remote. This is similar to an alarm feature. To avoid an Ignition trigger, use the remote for BOTH LOCKING and UNLOCKING the vehicle.
  • Page 11 GREEN NOT USED VIOLET NOT USED IGN. BLACK CHASSIS GROUND FUSE YELLOW (+) SWITCHED IGN "ON" GRAY OPT. (-) REMOTE OUTPUT 1 RELAY NOT USED BLACK/WHITE (-) DOME LIGHT OUTPUT DOME LIGHT CS-845RKE II BLUE BLUE BROWN/WHITE (-) HORN HONK/CHIRP OUTPUT THIS PLUG NOT USED...