Hitachi RA-08LEF Operation And Installation Manual

Window type room air conditioner

Advertisement

Quick Links

WINDOW TYPE ROOM AIR CONDITIONER
OPERATION AND INSTALLATION MANUAL
SAFETY PRECAUTION
Read the safety precautions carefully before operating the unit.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING ........ Incorrect methods of installation may cause death or serious injury.
CAUTION ......... Improper installation may result in serious consequence.
The sign in the À gure indicates prohibition.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit
as described in the user's manual.
PRECAUTIONS DURING INSTALLATION
Please ask sales agent or qualiÀ ed technician for the installation of the unit. Water leakage, short
circuit or À re may occur if install the unit improperly.
WARNING
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone.
Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit
CAUTION
breaker, the danger of electric shock exists.
Do not install near location where there is Á ammable gas. The unit may catch À re if Á ammable gas
leaks around it.
If drain pan is used, please ensure that when installing the drain hose, water is able to Á ow freely
without any obstruction.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
If abnormal situation arises (like burning smell), please stop the unit and turn off the circuit breaker.
Fault, short circuit or À re may occur if the unit is continue to operate under abnormal situation.
Please contact your agent for maintenance. Improper maintenance may cause electric shock and
À re.
WARNING
Please contact your agent if need to remove and reinstall the unit. Electric shock or À re
may occur if you remove and reinstall the unit improperly.
PARTS IDENTIFICATION AND OPERATIONS
Model
Width
Height
RA-08LEF
18
1
¼
", 470mm
13
1
¼
", 345mm
2
2
RA-10LEF
RA-13LEF
22
3
¼
", 560mm
14
3
¼
", 375mm
64
4
AUTO SWING
When the AUTO SWING switch is turned to "ON" position, the vertical deÁ ectors automatically oscillate right and left
sweeping the cold air alternately to obtain comfortable cooling.
The vertical deÁ ectors will stop to swing when the AUTO SWING switch is turned "OFF"
OPERATION MODE SELECTOR DIAL
OFF
Stop the fan and cooling operation.
Fan operation only at low speed.
LO FAN
HI FAN
Fan operation only at high speed.
Cooling operation with low fan speed. This is recommended for sleeping comfort.
LO COOL
HI COOL
Cooling operation with high fan speed for maximum cooling power.
The start of operation will occur an abnormal sound (turbo sound) which doesn't affect the operation.
<
>
IA1047: A
MODEL
RA-08LEF
RA-10LEF
RA-13LEF
Cabinet
1
Suction Grille
2
Front Cover
3
Horizontal DeÁ ectors
4
Vertical DeÁ ector
5
Air Exhaust Lever
6
Switch Panel Cover
7
Auto Swing Switch
8
Depth
Operation Mode Selection Dial
9
Thermostat Dial
10
25
3
¼
", 640mm
16
27
29
¼
", 709mm
32
THERMOSTAT DIAL
Setting the desired room temperature. Turn the dial further clockwise for cooler indoor temperature.
CAUTIONS
Do not set the dial to "TEST" for normal usage. This setting is only for technician. If the unit
is operate at "TEST" for normal use, it may cause the evaporator frosted and consequence
of no cooling, noisy and water leakage may be found.
If the evaporator is found frosted, it means the temperature at evaporator is too low. Please
turn the dial anti-clockwise and check if any obstacle in front of air outlet and inlet like curtain.
When the compressor stops, please wait 3 minutes before turning the dial clockwise.
AIR DEFLECTORS
VERTICAL DEFLECTORS
Vertical deÁ ectors at both sides of outlets can be set to
either auto-swing or static position to direct discharge air
rightward, leftward or forward direction.
CAUTIONS
To avoid dew forming on the deÁ ectors which eventually may drip to the Á oor, please do not adjust horizontal deÁ ectors
extremely downward position or vertical deÁ ectors extremely leftward or rightward position during cool operation for a long
time.
Also, do not adjust the vertical deÁ ectors position by hand or any other object.
AIR EXHAUST LEVER
Set the air exhaust lever to the down ( OPEN) position for air
ventilation in the room. The air exhaust lever should normally be kept
in up ( CLOSE) position during cooling operation and in the case of
typhoon.
AIR PURIFYING FILTER
Always stop the operation before installing the air purifying À lter.
1. Pull and remove the suction grille
Air purifying À lter is washable and can be use for 1 year time. Type number for this air purifying À lter is <SPX-CFH8W>.
Please use this number for ordering when you want to renew it.
NOTES ON OPERATION
TEMPERATURE AND HUMIDITY
Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). Recommended
operation humidity should be below 80%. Continuous operation at over 80% humidity (indoor) will cause some dews form
on the outlet grille and deÁ ectors of the unit.
NOISE
In a quiet environment during the starting or stopping the operation, phenomena like Á owing sound of refrigerant in the
refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is normal for the operation.
Water will be condensed on the evaporator coil and collected in the bottom tray, it is picked up by the condenser fan and
blown onto the condenser coil, this creates a "splashing" sound which is normal.
ODOR
The odor will possibly be emitted from the room air conditioner especially at the starting of operation and in a high
humidity condition. This is not abnormal phenomena because of the various kind of odors emitted by smoke, food stuffs,
cosmetics and others which may stick to the room air conditioner. So, the pre-À lter and the evaporator regularly must be
cleaned to reduce the odor.
THE IDEAL WAYS OF OPERATION
Install curtain or blinds
Suitable Ro
Temperature
Warning
Freezing temperature
is bad for health and a
waste of electric power.
Do Not Forget To Clean The Pre-Filter
Dusty pre-À lter will reduce the air
volume and the cooling efÀ ciency.
To prevent from wasting electric
energy, please clean the pre-À lter
every 20 days.
FOR USER'S INFORMATION
The Air Conditioner And The Heat Source In The Room
Caution
If the amount of heat in the room is above the cooling capability of the air conditioner (for
example: more people entering the room, using heating equipments and etc.), the preset
room temperature cannot be achieved.
When Lightning Occurs
Warning
To protect the unit during lightning, please stop operating the unit and remove the plug
from the socket.
HORIZONTAL DEFLECTORS
Horizontal deÁ ectors at both sides of the outlets can
be set to direct discharge air upward, downward or
forward direction.
2. Remove the pre-À lter
3. Install the air purifying À lter in
the frame
4. Install back the pre-À lter and
close the suction grille
Ventilation
Caution
It is possible
Do not close the room for a long period of
to reduce heat
time. Occasionally
entering the room
open the door and
through windows.
windows to allow the
entrance of fresh air.
Please Adjust Suitable Temperature
For Baby And Children
Please pay attention to the
room temperature and air Á ow
direction when operating the
unit for baby, children and old
people who have difÀ culty in
movement.

Advertisement

loading

Summary of Contents for Hitachi RA-08LEF

  • Page 1 THERMOSTAT DIAL MODEL Setting the desired room temperature. Turn the dial further clockwise for cooler indoor temperature. RA-08LEF RA-10LEF CAUTIONS RA-13LEF ● Do not set the dial to “TEST” for normal usage. This setting is only for technician. If the unit WINDOW TYPE ROOM AIR CONDITIONER is operate at “TEST”...