Note:
The proper subbase must be ordered to obtain the correct
electrical receptacle. (Figure 57)
8. After wiring is complete, mount covers A and F to the
subbase with provided screws. (Figure 54)
9. When installing optional accessories to the subbase, refer
to each installation instruction for that accessory.
Figure 53
Figure 54 - Part/Location Identification
Part/Location Identification
A
Left Front Cover
B
Right Front Cover
C
Front Cord Panel
D
Wall Sleeve Hole Location
E
Skirting Hole Location
F
Right Cover Assembly
Wall Sleeve
D
E
Cover
Wiring
A
B
Access
Subbase
Box Assembly
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
2-13/16"
D
(71 mm)
F
E
C
Low Voltage
Compartment
Figure 55 - Dimensions
Wall Sleeve
(Outdoor Side)
Ground
Screw Location
13-7/8" (352 mm)
Figure 56 - Wiring Diagram
Field Wiring
Line Voltage
NEMA 6-20R
Receptacle
NEMA 6-30R
Receptacle
230/208 VAC Field Schematic
Figure 57 - NEMA Plug Configurations
Voltage
Unit Plug
- 37 -
13 3/4"
2 3/4"
16"
16"
2 3/4"
2 5/8"
Left End View
Concentric
Knockouts In Bottom
Top View
Receptacle Provided
Inside subbase
Accessory
3-1/16"
(78 mm)
20-5/16" (515.5 mm)
Concentric
Knockouts In Rear
2" (50 mm) Max.
Adjustment
Front View
NEMA 7-20R
Receptacle
Field Wiring
Line Voltage
NEMA 7-30R
Receptacle
265 VAC Field Schematic
Subbase Receptacle
LGE Internal Use Only
Wall Sleeve
Inside Edge
Back of
Flange "A"