LG LP150HED-Y8 Service Manual page 35

Window air conditioner
Hide thumbs Also See for LP150HED-Y8:
Table of Contents

Advertisement

208/230 Volt Units
1. Remove and discard the white lead from the wire
assembly.
2. Connect the black lead to the line 2 terminal on the control
board.
3. Connect the red lead to the common (C) terminal on the
capacitor.
4. Connect the ground wire to the partition panel where the
ground wire on the power cord was located.
Use the supplied green ground screw.
5. Connect the red lead in the wire assembly at the junction
box to the red lead of the field power source.
6. Connect the black lead in the wire assembly at the junction
box to the black lead of the field power source.
7. Connect the ground wire of the field power source to the
ground wire of the wire assembly at the junction box.
8. Install the junction box cover plate.
9. Reinstall the control panel assembly.
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Figure 50 - Mounting Hard Wire Junction Box Kit
Cover plate
Conduit
Figure 51 - Metal Box Location
Control Panel
Figure 52 - Electrical Wiring Routing
Back of Control Panel
- 35 -
Wall Sleeve
Ground Wie
with Eyelet
Power Leads
28 Inch es Max
with Push on
Metal Box
with Straight Clamp
Base Pan
Bracket
Right Side of Chassis
Wire Tie
3/16 Inch
Diamenter Hole
Electrical Supply Wires
LGE Internal Use Only
Terminal
Connectors