PARAMETER
USER ACTIONS
Unlock
Press UNLOCK button (3)
Then type in your four-figure pin number using NUMBER buttons 0-9 (1).
The first time you adjust your sensor
Sensitivity
Press the SENSIVITY button (6).
Use NUMBER buttons 0-9 (1) to enter the sensitivity coefficient you want or
adjust this coefficient using the PLUS (2) or MINUS (4) buttons.
Repeat this operation to change the sensitivity again.
Hold time
Press the HOLD TIME button (5) and use NUMBER buttons 0-9 (1) to enter
the required hold time (up to 9 seconds).
Detection mode
Press the DETECTION MODE button (7).
(EAGLE 1 only)
Use NUMBER buttons 1-3 (1) to select the required mode :
button 1 : bidirectional mode
2 : unidirectional mode
3 : unidirectional mode with MTF function
Relay
Press the RELAY CONFIGURATION button (11) and use NUMBER buttons 1-4 (1)
configuration
to select the required relay configuration :
button 1 : active output, relay contact closed during detection,
2 : passive output, relay contact open during detection,
3 : continuous detection, relay contact always closed
4 : continuous non-detection, relay contact always open
Immunity
Press the IMMUNITY button (8).
Use NUMBER buttons 1-3 (1) to select the type of digital filter required :
button 1 : detection of quasi-presence
2 : norma
3 : increased immunity
Lock
When all the parameters have been recorded, press the LOCK button (10).
If you wish to enter a new access code, use NUMBER keys 0-9 to enter the new
four-figure code within 10 seconds. It must begin with 1.
If you want to keep the current access code, press a second time the LOCK
button (10).
When the remote-controlled configuration of the sensor is complete, you can find out the values entered for the
parameters at any time in the following way :
PARAMETERS
USER ACTIONS
Check values
Press the button for the parameter whose value you wish to check (button 5, 6, 7, 8, 11), then press the CHECK VALUES
button (9). Then simply count the number of times the LED flashes. This corresponds to the status of the parameter in
question. Repeat the operation to find out the status of the other parameters.
eg :
• detection mode button - 2 flashes
• sensitivity button - 6 flashes
When the remote-controlled configuration of the sensor is complete, you can reset all the parameters to their factory values
by means of the following procedure :
PARAMETERS
USER ACTIONS
Default
Press the DEFAULT VALUE button (12), then press the number button 1. All the parameters are reset to their factory values.
In case of high mounting, the sensor can be configured in order to be more sensitive : before adjusting the sensor, press the DEFAULT VALUE button (12).
Then press the number button 2. All the parameters are reset to their factory values but the sensor has now an increased sensitivity scale. Then adjust the
other parameters.
Should you come back to the standard sensitivity scale, repeat the procedure with the DEFAULT VALUE button followed by 1.
* Note : when your access code is reset to the factory value (0000) you can access adjustment mode directly without the
need to re-enter this code.
All data checked with the maximum care. However, no liability is accepted for any error or omission. The declaration de conformity and other technical documentation
are available on our website www.came.it - BUY-TO-SELL PRODUCT
*
, enter the factory value code (0000).
open during non-detection
closed during non-detection
the parameter is set in unidirectional mode
the parameter is set at 6
FACTORY SETTING
LED STATUS
0000
The LED flashes slowly to indicate that an
adjustment session is under way.
7
The LED flashes more rapidly while the unit waits
for the corresponding numerical value.
It then continues to flash more slowly.
0,5 seconds
The LED flashes more rapidly while the unit waits
for the corresponding numerical value.
It then continues to flash more slowly.
unidirectional
The LED flashes more rapidly while the unit waits
for EAGLE 1
for the corresponding numerical value.
with MTF function
It then continues to flash more slowly.
bidirectional
for EAGLE 2
active output
The LED flashes more rapidly while the unit waits
for the corresponding numerical value.
It then continues to flash more slowly.
Normal
The LED flashes more rapidly while the unit waits
for the corresponding numerical value.
It then continues to flash more slowly.
0000
The LED stops flashing to return to its normal
function.
7