Hitachi Z-3000W Operating Instructions Manual page 51

Table of Contents

Advertisement

White and black balance adjustment
Auto white balance error messages
If auto white balance adjustment fails, the following error messages appear on the viewfinder screen for about 6
seconds.
Message
  AUTO WHITE : NG
  CHANGE TO CAM
  TRY AGAIN
  AUTO WHITE : NG
CHANGE  WHITE  BAL  TO  A/B
  TRY AGAIN
  AUTO WHITE : NG
CHANGE  WHITE  BAL  TO  MEM
  TRY AGAIN
  AUTO WHITE : NG
  LOW LIGHT
  TRY AGAIN
  AUTO WHITE : NG
  LEVEL HIGH
  TRY AGAIN
  AUTO WHITE : NG
  C.TEMP HIGH
  CHANGE FILTER
  TRY AGAIN
  AUTO WHITE : NG
  C.TEMP LOW
  CHANGE FILTER
  TRY AGAIN
  AUTO WHITE :
  TALLY ON
  EXECUTE?
When the above error messages appear, correct the settings and repeat white balance adjustment.
White balance memory
The adjustment values for each folder can be automatically stored in the respective memory (A or B) according to
the White BAL switch setting. The total of 4 folders allows storing 8 adjustment values.
Cause
Output switch set to BAR.
White BAL switch at PRE, or Full Auto
is on (local mode).
White BAL switch not at MEM (remote
mode).
Lighting insufficient for adjustment.
Excessive lighting for adjustment.
Color temperature too high for
adjustment.
Color temperature too low for
adjustment.
Tally lamp lighted.
Change switch setting to CAM and readjust.
Set White BAL switch to A or B, or Full Auto
to off, then readjust.
Set switch to MEM and readjust.
Increase the lighting or set the Gain switch to
M or H. If manual iris lens, adjust the lens.
Then repeat white balance adjustment.
Set Gain switch to a lower position.
If manual iris lens, adjust the lens.
Then repeat white balance adjustment.
Change optical filter and readjust.
While lighted, again set the Auto W/B BAL
switch to AWB and begin adjustment.
38
Correction

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z-3000

Table of Contents