• Control system program can operate the switch via digital, analog, and serial control • QuickMedia ports include Cresnet distribution to simplify termination of QuickMedia and Cresnet wiring 8X8 QuickMedia™ Switcher: QM-MD8X8 • 1 ® ® ports with 24VDC power...
8X8 QuickMedia™ Matrix Switcher Applications The following diagrams show a QM-MD8X8 in a lecture hall application and a business application. QM-MD8X8 in a Lecture Hall Application 2 • 8X8 QuickMedia™ Switcher: QM-MD8X8 Crestron QM-MD8X8 Operations Guide – DOC. 6260A...
Page 7
QM-MD8X8 in a Business Application For more information on this and other QM applications, refer to the latest revision of the Crestron MediaManager Applications Guide (Doc. 6244) which is available from the Crestron website (http://www.crestron.com/manuals). Operations Guide – DOC. 6260A 8X8 QuickMedia™...
Internal Block Diagram The following diagram represents the switching abilities of the QM-MD8X8. The QM-MD8X8 can be operated locally (local mode) using buttons on the front panel, or remotely from a control system (system mode). For more information, refer to “Operating Modes”...
Page 9
Crestron QM-MD8X8 Up to two tiers of QM-MD8X8s can be cascaded to provide up to 64 QM inputs through one QM-MD8X8 as shown in the following block diagram. Multiple QM-MD8X8s Cascaded to One QM-MD8X8 Operations Guide – DOC. 6260A 8X8 QuickMedia™ Matrix Switcher...
8X8 QuickMedia™ Matrix Switcher Specifications Specifications for the QM-MD8X8 are listed in the following table. QM-MD8X8 Specifications Physical Description This section provides information on the connections, controls, and indicators available on your QM-MD8X8. QM-MD8X8 Physical View (front) 6 • 8X8 QuickMedia™ Switcher: QM-MD8X8...
Page 11
Operations Guide – DOC. 6260A 8X8 QuickMedia™ Matrix Switcher 17.03 in (43.24 cm) 16.92 in (42.98 cm) CONNECTORS, CONTROLS, & INDICATORS PWR LED Indicates 24 Volts DC power supplied from Cresnet control network. 8X8 QuickMedia™ Switcher: QM-MD8X8 • 7 6.64 in (16.86 cm) DESCRIPTION...
Page 12
8X8 QuickMedia™ Matrix Switcher Connectors, Controls, & Indicators (continued) (continued on following page) 8 • 8X8 QuickMedia™ Switcher: QM-MD8X8 CONNECTORS, CONTROLS, & INDICATORS NET LED Indicates communication with Cresnet System. AUDIO BREAK When in Local mode, enables audio break. When in System mode, LED indicates audio break is enabled.
Crestron QM-MD8X8 Connectors, Controls, & Indicators (continued) Industry Compliance As of the date of manufacture, the QM-MD8X8 has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Operations Guide – DOC. 6260A 8X8 QuickMedia™...
Page 14
10 • 8X8 QuickMedia™ Switcher: QM-MD8X8 Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.
Installations are flexible, affordable, and fast. For more information, refer to the latest revision of the Crestron MediaManager Applications Guide (Doc. 6244) which is available for download from the Crestron website. CRESCAT-QM Cable NOTE: Do not untwist the two wires in a single pair for more than 1/3-1/2”...
8X8 QuickMedia™ Matrix Switcher Identity Code The Net ID of the QM-MD8X8 has been factory set to 06. The Net IDs of multiple QM-MD8X8 devices in the same system must be unique. Net IDs are changed from a personal computer (PC) via the Crestron Toolbox. When setting the Net ID, consider the following: For more details, refer to the Crestron Toolbox help file.
Page 17
75 watts of power to each group of QM ports to ensure that sufficient power is available for QM devices that are connected to the QM-MD8X8. The C2N-SPWS300 can also supply the power required by the QM-MD8X8.
Page 18
C2N-SPWS300 System Power Supply Operations Guide (Doc. 8190). NOTE: Power to the QM ports on the QM-MD8X8 can be applied using other configurations. The total power usage of each port group must not exceed the port group’s available input power.
Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestron’s True Blue Support, log in at http://support.crestron.com.
8X8 QuickMedia™ Matrix Switcher Programming with SIMPL Windows NOTE: While SIMPL Windows can be used to program the QM-MD8X8, it is recommended to use SystemBuilder and Digital Media Tools software for configuring and tuning a QuickMedia system. SIMPL Windows is Crestron’s premier software for programming Crestron control systems.
Detail View. A description for each signal in the symbol is described in the SIMPL Windows help file (F1). Example Program An example program for the QM-MD8X8 is available from the “Example Program” section of the Crestron website (http://www.crestron.com/exampleprograms). Search for qm_8X8_demo.ZIP.
Establishing Communication Use Crestron Toolbox for communicating with the QM-MD8X8; refer to the Crestron Toolbox help file for details. There is a single method of communication; indirect communication via the control system. Indirect Communication via Control System Programs and Firmware For details on uploading and upgrading, refer to the SIMPL Windows help file or the Crestron Toolbox help file.
System mode. Local Mode Operation-Switching Signal Routing Signals coming in to the QM-MD8X8 can be switched to individual or multiple output locations. Additionally, the audio and video portions of an input signal can be switched simultaneously or separately.
Page 24
NOTE: If ENTER has not been pressed, you can go back and “undo” changes made to the current routing. 1. Press LOCAL to place the QM-MD8X8 in the Local mode (the LOCAL LED is flashing slowly). 2. Press AUDIO BREAK to turn on the audio break function. The AUDIO BREAK and A LEDs will turn on.
When calculating the length of wire for a particular Cresnet run, the wire gauge and the Cresnet power usage of each network unit to be connected must be taken into consideration. Use Crestron Certified Wire only. If Cresnet units are to be daisy- Operations Guide – DOC. 6260A 8X8 QuickMedia™...
Cresnet power usage of the entire chain. If the unit is a home-run from a Crestron system power supply network port, the Cresnet power usage of that unit is the Cresnet power usage of the entire run. The wire gauge and the Cresnet power usage of the run should be used in the following equation to calculate the cable length value on the equation’s left side.
Crestron QM-MD8X8 Future Updates As Crestron improves functions, adds new features, and extends the capabilities of the QM-MD8X8, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.
(property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party.
Page 29
Crestron QM-MD8X8 8X8 QuickMedia™ Matrix Switcher This page is intentionally left blank. 8X8 QuickMedia™ Switcher: QM-MD8X8 • 25 Operations Guide – DOC. 6260A...
Page 30
8X8 QuickMedia™ Matrix Switcher Crestron QM-MD8X8 This page is intentionally left blank. 26 • 8X8 QuickMedia™ Switcher: QM-MD8X8 Operations Guide – DOC. 6260A...
Page 31
Crestron QM-MD8X8 8X8 QuickMedia™ Matrix Switcher This page is intentionally left blank. 8X8 QuickMedia™ Switcher: QM-MD8X8 • 27 Operations Guide – DOC. 6260A...
Page 32
Crestron Electronics, Inc. Operations Guide – DOC. 6260A 15 Volvo Drive Rockleigh, NJ 07647 (2009922) Tel: 888.CRESTRON 02.06 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.
Need help?
Do you have a question about the QuickMedia QM-MD8X8 and is the answer not in the manual?
Questions and answers