Troubleshooting

7.2

Factory reset Key

▶ In order to carry out the factory reset, press the key on Key
longer than 5 seconds.
The Key loses all connections and then goes directly into
the pairing mode, i.e. it flashes yellow for up to 3 minutes
and all wireless participants must be reconnected.
Before the wireless participants can be reconnected, they must
first be separated. To do this, separate the control unit by
means of the service menu (installer). Separate the outside
temperature sensor by means of a reset.
8
Troubleshooting
If a fault cannot be corrected:
▶ Confirm the fault.
▶ Faults that are still active are displayed once again the next
time the control unit returns from the idle state.
▶ Call an authorised specialist or customer service and give
the fault code and sub-code, as well as the ID number of the
user interface.
_
_
Table 9
Your contractor must enter the ID no. here.
8.1
Troubleshooting
Structure of table headers:
code - [cause or fault description].
In the event of a fault, a code is displayed.
[blank display or low battery symbol]
Description
Batteries are used up.
Table 10
207 - [low system pressure]
Description
System pressure is low.
Table 11
18
_
Action
Replace the batteries.
Action
Fill system.
1004 - [fault in other control unit]
Description
Another control unit in the
system has developed a fault.
Table 12
1007 - [no wireless signal]
Description
Control unit has no wireless
connection with Key.
Table 13
1009 - [no wireless signal or connection failed]
Description
Control unit has no wireless
connection with Key.
Table 14
1010 - [no communication with heat source via EMS-BUS]
Description
No communication, although
heat source is EMS-
compatible.
Table 15
1017- [system pressure too low]
Description
System pressure is too low.
Table 16
1037 - [Weather-compensated control without outside
temperature sensor]
Description
Weather-compensated
control is set. No outside
temperature sensor is
connected or the batteries of
the outside temperature
sensor are flat.
Table 17
Comfort+ II RF – 6720892636 (2019/04)
Action
Check other control units in
the system for faults.
Action
Check the signal strength and
position the control unit in a
better place.
Action
Reconnect wireless device.
Action
Replace EMS connections/
interfaces.
Action
Fill system.
Action
Select room temperature-
dependent controls or
connect outside temperature
sensor.
Replace batteries of the
outside temperature sensor.