Do you have a question about the Comfort+ II RF and is the answer not in the manual?
Questions and answers
Jill Bebbington gton
January 17, 2025
On turning on our heating off overnight key lock signal is showing. The boiler is producing hot water so is eorking
1 comments:
Mr. Anderson
February 3, 2025
The key lock signal on the Worcester Comfort+ II RF indicates that the control unit is locked, preventing interaction with it. It does not specifically relate to the heating being turned off overnight but signifies that the keys and selector are inactive until the key lock is deactivated.
▶ If DHW temperatures above 60 °C are set or if thermal disinfection is The info symbol indicates important information where there is activated, a mixer must be installed. no risk to people or property. If in doubt, ask your installer. Comfort+ II RF – 6720892636 (2019/04)
DHW heating via a heating controller with conveniently from the living space which means the modulation. Up to six switching times can be set in the central Comfort+ II RF is the perfect choice for heat sources that are heating and DHW program. difficult to access.
Technical documentation for the heat source. 0010021545-002 These instructions contain the installation and operating Fig. 2 instructions for the Comfort+ II RF control unit. [1] Connect the Key [2] LED on the Key Installation and commissioning key Description of the LED displays...
Do not mount the control unit on a wall where it will be exposed to sunlight or draughts, preferably on an inside wall 1.2 m above the floor. The control unit must not be directly influenced by radiators or heat-emitting objects, such as TVs or table lamps. Comfort+ II RF – 6720892636 (2019/04)
[6] Frost protection (lights up in heating mode Off) ▶ Install the wall socket horizontally. [7] am or pm (lights up if 12-hour time format is used) [8] Heating operating mode [9] Battery low Comfort+ II RF – 6720892636 (2019/04)
To deactivate the key block: ▶ Press and hold the select heating key and selector simultaneously until Key lock is no longer displayed. After a short time, the standard display reappears. Comfort+ II RF – 6720892636 (2019/04)
▶ Press the selector. Time setting 2 is displayed. The hours display flashes. ▶ Set Time setting 2 and Temp. setting 2. ▶ Set or deactivate Time setting 3 up to Temp. setting 6 ( Chapter 5.3). Comfort+ II RF – 6720892636 (2019/04)
– Thursday Time program is reset. – Friday – Saturday – Sunday ▶ Press the selector. DHW 1 on is displayed. The hours display flashes. ▶ Turn the selector if necessary to set the hour. Comfort+ II RF – 6720892636 (2019/04)
▶ Press the selector. Holiday prog. and On is displayed. ▶ Press the selector. On flashes. ▶ Turn the selector to select Off. ▶ Press the selector. ▶ Press the key to return to the standard display. Comfort+ II RF – 6720892636 (2019/04)
▶ Turn the selector to select Date format. – FR (French) ▶ Press the selector. ▶ Press the selector. ▶ Turn the selector to select DD.MM.YYYY or MM/DD/ YYYY. ▶ Press the selector. Date format is displayed after a few seconds. Comfort+ II RF – 6720892636 (2019/04)
▶ Turn the selector to select Format. The following functions are only used by specialists. ▶ Press the selector. They are used for the installation of the Comfort+ II RF or for ▶ Turn the selector to select Time format. troubleshooting.
▶ Turn selector to select Heat. Algorithm are set. ▶ Press the selector. The available control types are displayed. ▶ Turn selector to select the desired control type. ▶ Press the selector. ▶ Press to return to Heat.circuit. Comfort+ II RF – 6720892636 (2019/04)
– Underfloor heating (floor) or as confirmation on the display. – To select conventional heating (heating). ▶ Press the selector to confirm the selection. ▶ Press "Back" to return to "Type of Heating Circuit". Comfort+ II RF – 6720892636 (2019/04)
Page 16
The reference outside temperature for the measurement of the and 50 °C for a heating circuit of the type "underfloor heating". heating elements can be set at a resolution of 1 °C between - 20 °C and 0 °C. Comfort+ II RF – 6720892636 (2019/04)
The reference outside temperature used for the If the pairing is not successful, i.e. no new wireless participant measurement of the heating elements was connected, the LED 5 flashes red for seconds. Comfort+ II RF – 6720892636 (2019/04)
Table 10 the outside temperature Replace batteries of the sensor are flat. outside temperature sensor. 207 - [low system pressure] Table 17 Description Action System pressure is low. Fill system. Table 11 Comfort+ II RF – 6720892636 (2019/04)
60 days, otherwise the programmed settings are lost. ▶ Replace the batteries with new ones of the same type: LR6/ AA 1.5 V Alkaline. Fig. 17 Replace batteries Comfort+ II RF – 6720892636 (2019/04)
Regulation 811/2013 for the identification of integrated pressure test systems Pollution degree Contribution to seasonal energy efficiency of central Table 23 Wireless technology in Comfort+ II RF and Key heating in % Environmental protection/disposal Simplified EU Declaration of Conformity regarding radio equipment...
– System Pressure – Outdoor temp. – DHW 1) Set language. – Actual temp – Signal strength 2) This menu item is only available if the weather- – Energy Consumption compensated control was previously set. Comfort+ II RF – 6720892636 (2019/04)
Need help?
Do you have a question about the Comfort+ II RF and is the answer not in the manual?
Questions and answers
On turning on our heating off overnight key lock signal is showing. The boiler is producing hot water so is eorking
The key lock signal on the Worcester Comfort+ II RF indicates that the control unit is locked, preventing interaction with it. It does not specifically relate to the heating being turned off overnight but signifies that the keys and selector are inactive until the key lock is deactivated.
This answer is automatically generated
What does Na mean for DHW