Fault
The light does not function.
Controls have reduced
luminosity.
Appliance is not cooling,
temperature display and light
are lit.
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
The appliance has no
refrigeration capacity.
The lighting does not work.
The display does not
illuminate.
20
Possible cause
The LED light is defective.
Appliance was open too
long.
Light is switched off after
approx. 10 min.
When the appliance is not
used for some time,
the display on the fascia
switches to energy saving
mode.
Showroom mode is
switched on.
The evaporator (refrigeration
generator) in the NoFrost
system is covered in thick ice
and can no
longer be defrosted fully
automatically.
Power failure
The fuse has been switched
off.
The mains plug has not been
inserted properly.
Remedial action
See chapter "Light (LED)" section.
When the appliance is closed and opened,
the light is on again.
As soon as the appliance is again used, e.g.
the door is opened, the display switches back
to normal illumination.
Hold down temperature selection button
fig. "/1 for 10 seconds until
an acknowledgement signal sounds.
After a short time check whether your
appliance is cooling.
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance. Fig. *
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
Check whether the power is on. In the event of
a longer power failure, condensation will
collect in the condensation channel. Wipe up
the condensation water with a soft cloth.
Check mains fuse.
Check whether the mains plug is securely
inserted.