Vertex Standard GX1256S Alignment Manual
Vertex Standard GX1256S Alignment Manual

Vertex Standard GX1256S Alignment Manual

Advertisement

Quick Links

The GX1256S has been carefully aligned at the factory for the specified performance
across the marine band.
Realignment should therefore not be necessary except in the event of a component
failure. All component replacement and service should be performed only by an authorized
Standard Horizon representative, or the warranty policy may be voided.
The following procedures cover the sometimes critical and tedious adjustments that are
not normally required once the transceiver has left the factory. However, if damage occurs
and some parts are replaced, realignment may be required. If a sudden problem occurs
during normal operation, it is likely due to component failure; realignment should not be
done until after the faulty component has been replaced.
We recommend that servicing be performed only by authorized Standard Horizon
service technicians who are experienced with the circuitry and fully equipped for repair and
alignment. Therefore, if a fault is suspected, contact the dealer from whom the transceiver
was purchased for instructions regarding repair. Authorized Standard Horizon service
technicians realign all circuits and make complete performance checks to ensure
compliance with factory specifications after replacing any faulty components.
Those who do undertake any of the following alignments are cautioned to proceed at
their own risk. Problems caused by unauthorized attempts at realignment are not covered
by the warranty policy. Also, Standard Horizon, a division of VERTEX STANDARD, must
reserve the right to change circuits and alignment procedures in the interest of improved
performance, without notifying owners. Under no circumstances should any alignment be
attempted unless the normal function and operation of the transceiver are clearly
understood, the cause of the malfunction has been clearly pinpointed and any faulty
components replaced, and the need for realignment determined to be absolutely necessary.
The following test equipment (and thorough familiarity with its correct use) is necessary
for complete realignment. Correction of problems caused by misalignment resulting from
use of improper test equipment is not covered under the warranty policy. While most steps
do not require all of the equipment listed, the interactions of some adjustments may require
that more complex adjustments be performed afterwards. Do not attempt to perform only a
single step unless it is clearly isolated electrically from all other steps. Have all test
equipment ready before beginning, and follow all of the steps in a section in the order
presented.
GX1256S Alignment
1/7
FCC ID: K6630053X30
IC ID: 511B-30053X30
Alignment
Vertex Standard Co,. Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GX1256S and is the answer not in the manual?

Questions and answers

Summary of Contents for Vertex Standard GX1256S

  • Page 1 IC ID: 511B-30053X30 Alignment GX1256S Alignment The GX1256S has been carefully aligned at the factory for the specified performance across the marine band. Realignment should therefore not be necessary except in the event of a component failure. All component replacement and service should be performed only by an authorized Standard Horizon representative, or the warranty policy may be voided.
  • Page 2 Overview of Test Mode The test mode has been build in the microprocessor in order to adjust and confirm the performance of transceiver. The purpose is to adjust transceiver simply and to confirm the performance of transceiver smoothly. Vertex Standard Co,. Ltd.
  • Page 3 Adjustment and Confirmation of Transmit Power Adjust power at high and low in the transmit mode, and confirm power in the specified bandwidth. -- Adjustment -- Connect the wattmeter and 50-ohm dummy load to the antenna jack. Vertex Standard Co,. Ltd.
  • Page 4 ±4.4 KHz to ±4.6 KHz. -- Confirmation -- Set the output of the AG to 1 KHz and 150 mV. Set the channel to EXP01, confirm that maximum deviation is between ±4.3 KHz and Vertex Standard Co,. Ltd.
  • Page 5 It is impotent to take the lowest possible value at the stop band near 150 MHz and the highest possible value at the band near 156 MHz. Each coil shall be adjusted at the range between the initial condition and right and left revolving. Vertex Standard Co,. Ltd.
  • Page 6 In 3 seconds, send the INDIVIDUAL CALL from the confirmation transceiver. Confirm that the test transceiver receives the INDIVIDUAL CALL from the confirmation transceiver and outputs the beep. Press the CALL/SET key of the test transceiver and turn off the beep. Vertex Standard Co,. Ltd.
  • Page 7 Confirm that the confirmation transceiver receives the response from the test transceiver and outputs beep. Press the CALL/SET key of the confirmation transceiver and turn off the beep. Simultaneously, confirm that “TEST” of test transceiver’s MMSI is displayed in the LCD of the confirmation transceiver. Vertex Standard Co,. Ltd.

Table of Contents