Cisco ASR 902 Troubleshooting Manual page 8

Hide thumbs Also See for ASR 902:
Table of Contents

Advertisement

RJ-45 Connector Pinouts
Note
Twisted pairs are 2-5, 6-8, 4-7.
Note
The X.21, V.35, RS-485, EIA-449, EIA-530, and IRIG-B standards are not currently supported by software.
RJ-45 Connector Pinouts
The table below summarizes the pinouts for each serial interface type when using an RJ-45 connector.
Table 12: RJ45 Pinout
Pi n
1
2
3
4
5
6
7
8
Note
Twisted Pairs are: 1-2, 3-6, 4-5, 7-8.
Note
The X.21, V.35, RS-485, EIA-449, EIA-530, and IRIG-B standards are not currently supported by software.
Management Ethernet Port Pinouts
A single management copper Ethernet port supporting 10/100/1000Base-T operation exists on each RSP.
There is no direct access to the CPU of the other RSP. The Management Ethernet port uses a standard RJ45
jack.
Troubleshooting
8
Standard
Direction
Description
DB-9
RTS
Input
Ready to
send
DTR
Input
DTR
TxD
Input
Transmit
GND
Signal
ground
GND
Signal
ground
RxD
Output
Receive data
DST
Output
DSR
CTS
Output
CTS
RS-485
IRIG-B
RxD+
NC
(RS485)
RxD- (RS485)
NC
NC
NC
Gnd
Gnd
Gnd
Gnd
-
IRIG-B (RS232)
TxD-
IRIG-B- (RS485)
TxD+
IRIG-B+
(RS485)
Troubleshooting

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asr 902u

Table of Contents