Gigabyte H262-NO0 User Manual page 15

Table of Contents

Advertisement

System
Management
Power Supply
Ambient
Temperature
Relative
Humidity
System
Dimension
Hardware Installation
Aspeed® AST2600 management controller (H262-NO0/H262-PC1)
Š
Aspeed® AST2500 management controller (H262-PC0)
Š
AMI MegaRAC SP-X Solution Web interface
Š
Dashboard
Š
JAVA Based Serial Over LAN
Š
HTML5 KVM
Š
Sensor Monitor (Voltage, RPM, Temperature, CPU Status ...etc.)
Š
Sensor Reading History Data
Š
FRU Information
Š
SEL Log in Linear Storage / Circular Storage Policy
Š
Hardware Inventory
Š
Fan Profile
Š
System Firewall
Š
Power Consumption
Š
Power Control
Š
LDAP / AD / RADIUS Support
Š
Backup & Restore Configuration
Š
Remote BIOS/BMC/CPLD Update
Š
Event Log Filter
Š
User Management
Š
Media Redirection Settings
Š
PAM Order Settings
Š
SSL Settings
Š
SMTP Settings
Š
2 x 2200W redundant PSUs
Š
80 PLUS Platinum
Š
AC Input:
Š
100-127V~/ 14A, 47-63Hz
200-240V~/ 12.6A, 47-63Hz
DC Output:
Š
Max 1200W/ 100-127V~
+12.12V/ 95.6A
+12Vsb/ 3.5A
- Max 2200W/ 200-240V
+12.12V/ 178.1A
+12Vsb/ 3.5A
Operating temperature: 10°C to 35°C
Š
Operating humidity: 8-80% (non-condensing)
Š
Non-operating temperature: -40°C to 60°C
Š
Non-operating humidity: 20%-95% (non-condensing)
Š
2U 4 Nodes - Rear access
Š
440mm (W) x 87mm (H) x 840mm (D)
Š
- 15 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

H262-pc0H262-pc1

Table of Contents