❷ Installation

2.1 I Selecting the location

• The appliance must be installed in a technical room ventilated, dry and without stored pool
treatment products.
• The appliance must be installed before any water treatment system.
• Install the appliance as close as possible to the heating source (boiler, heat pump, geothermal, solar-powered heating,
etc.),
• If the appliance cannot be installed beside the heating source:
- Provide for the dimensioning of the pipes and primary and secondary circuits in relation to the water flow rate, the
losses of load and the distance, and insulate them thermally.
- Install a more powerful circulating pump (contact a qualified professional for its dimensioning).
• If the exchanger is a long way from the filter, for the pool circuit use a system of Ø50 or Ø63 pipes (if the overall length
of the circuit is greater than 30 metres). If the pipes are installed underground, they should be in protective sleeves.
• Preferably, the exchanger should be installed at the low point so that it is always full of water.
• The water treatment system must be installed at a low point to avoid chlorine being returned to the exchanger.
• Leave at least 80 cm free space around the appliance to facilitate its installation and maintenance,
• The pipes must not be supported by the exchanger.
• The appliance must be secured horizontally to the wall of the technical room:
- Bare Heat Line: using brackets (not included).
- Heat Line Plus and without circulating pump: using the holes at the back of the switch box and 4 screws (not
included).
IMPORTANT: Do not attach the appliance using adhesive tape.