Download Print this page

MTS Systems MAXPLUS 211 Manual page 14

Option spindle amplifier

Advertisement

The location of these adjustments is directly below the I/O wiring.
Outputs
Two diagnostic outputs are the dc voltage proportional to velocity and the dc output
proportional to current/torque. The nominal TAC gradient changes based on the selected
speed ranges of 1200, 2400 and 4200 rpm, and is ±1 volt per 1000 rpm. The current gradient
is 10 volts equals the continuous rating.
14
NOTE
The pot labeled AUX controls the speed of
the spindle orient feature and need not be
adjusted by the user.
FEEDBACK AND I/O CONTROL ASSEMBLY
ENCODER
I/O
GND
ORIENT
BAL
RAMPS
GND
CUR
-COM
+COM
CUR
RESP
TAC
SIG
GND
FLT
AUX
SHFT
SLOW
SPD
ENB
RESET