areas where the temperature is colder than 40 degrees Fahrenheit (4.4 Celsius) or hotter
than 100 degrees Fahrenheit (37.8 Celsius). Place away from doors and windows that open
to the outside.
Step 2
Mounting Instructions::
1. Remove the mounting bracket from the back of the alarm by twisting the alarm.
2. After selecting the proper location for your CO Alarm, drilling two Ø5.0mm holes in the
ceiling or wall vertically with the distance of 60mm and inserting one plastic insert into the
holes, then attaching the bracket to the plastic insert with the arrow down to the ground and
screwing tightly two screws in the two inserts.
3. Matching the arrow on the back of the alarm with the arrow on the bracket to snap the
alarm on the bracket by twisting the alarm.
Step 3
Testing the Alarm:
CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms
length away from the unit when testing.
Once the detector is installed, start the test / test mode by pressing the test button for 5
seconds. The detector will emit a series of beeps.
The test/reset button has two purposes. It tests the unit's electronics and reset the unit
during CO or smoke alarm. After installation, TEST THE UNITS ELECTRONICS by pressing
the test button for five seconds. A series of beeps will sound. If the unit chirps and red LED
flashes once every 30 seconds with green LED not flashing once every 30 seconds, that
means the unit is malfunctioning. You need to return the unit to our agent for repairing.
If the alarm is sounding, pressing the button will silence the alarm for several minutes. After
the duration, if the CO condition that caused the alert continues, the alarm will reactivate.
The duration spans from 2 minutes to 6 minutes. The unit needs to be tested weekly! If
at anytime it does not perform as described, verify power is connected correctly and that
the battery doesn't need replacing. Clean dust and other buildup off the unit. If it still doesn't
operate properly call our agent.
Operation Instructions
Test Feature
Press the test button for several seconds to test unit's electronics. The alarm will sound.
LED Indicator Operation
Red LED
Red Led will flash in conjunction with the alarm beep. Therefore, the red LED will flash during
a CO or smoke alarm, a low battery mode chirp and a malfunction status. As you install the
battery on the unit, the unit will sound 'chirp' to indicate the battery installed properly.
Green LED
Green LED flashes once every 30 seconds to indicate proper operation and it is out to
indicate malfunctioning.
What To Do IF The Alarm Sounds
If alarm sounds:
• Call your emergency services.
• Immediately move to fresh air – outdoors or by an open door/window. Do a head count
to check that all persons are accounted for. Do not reenter the premises nor move away
from the open door/window until the emergency services responders have arrived, the
premises have been aired out, and your alarm remains in its normal condition.
Never restart the source of a CO problem until it has been fixed. NEVER IGNORE THE
ALARM!
The sensitivity of the CO detector is 100 +/- 50ppm in concentration and the sensitivity of the
smoke detector is 1 ~ 5% / ft OBS.
This carbon monoxide alarm is designed to detect carbon monoxide gas fromANY
source of combustion. It is NOT designed to detect any other gas.
Fire departments, most utility companies will perform CO inspections, some may charge
for this service.
Battery Replacement
If a battery failure is detected, the unit will beep every 30 seconds.
CAUTION: YOUR ALARM IS SEALED AND THE COVER IS NOT REMOVABLE!
To replace the battery you must first remove the alarm from the screws then open the battery
door, then you can directly replace the battery.
After installing or changing the battery, reinstall your alarm. Test your alarm by using the test
button and check that the red LED flashing once every 30 seconds.
Replace battery with qualified brands.
CAUTION: Don't press test/reset button while installing batteries. Otherwise, the unit
will not work.
Use only the specified batteries. Using different or incorrect batteries can damage
the detector and alarm. A good safety measure would be to change the battery once
a year.
General Maintenance
To keep your CO + Smoke Alarm in good working order, please follow these simple steps:
- Verify the unit's alarm and LED light operation by pushing the test button once a week.
Remove the unit from mounting bracket and vacuum the alarm cover and vents with a soft
brush attachment once a month to remove dust and dirt.
REINSTALL IMMMEDIATELYAFTER CLEANING AND THEN TEST USING THE TEST/
RESET BUTTON!
• Never use detergents or other solvents to clean the unit.
• Avoid spraying air fresheners, hair spray, or other aerosols near the CO Alarm.
• Do not paint the unit. Paint will seal the vents and interfere with the sensor's ability to
detect CO. Never attempt to disassemble the unit or clean inside. This action will void
your warranty.
WARNING: Reinstall the CO Alarm as soon as possible to assure continuous protection.
When household cleaning supplies or similar contaminates are used, the area must be well
ventilated. The following substances can affect the CO sensor and may cause false readings
and damage to the sensor: Methane, propane, iso-butane, iso-propanol, ethyl acetate,
hydrogen sulfide dioxides, and alcohol based products, paints, thinner, solvents, adhesives,
hair spray, after shave, perfume, and some cleaning agents.
Carbon Monoxide Safety Information
Symptoms of CO poisoning
Initial carbon monoxide poisoning symptoms are similar to the flu with no fever and can
include dizziness, severe headaches, nausea, vomiting and disorientation. Everyone is
susceptible but experts agree that unborn babies, pregnant women, senior citizens and
people with heart or respiratory problems are especially vulnerable. If symptoms of carbon
monoxide poisoning are experienced seek medical attention immediately. CO poisoning can
be determined by a carboxyhemoglobin test.
The following symptoms are related to CARBON MONOXIDE POISONING and should be
discussed with ALL members of the household:
• Mild Exposure: Slight headache, nausea, vomiting, fatigue (often described as 'Flu-like'
symptoms).
• Medium Exposure: Severe throbbing headache, drowsiness, confusion, fast heat rate.
• Extreme Exposure: Unconsciousness, convulsions, cardiorespiratory failure, death.
FULL MANUAL DOWNLOAD
MANUFACTURER:
MGL International
APAC: MGL GLOBAL SOLUTIONS LTD
info.apac@mgl-intl.com
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA: MGL EUMAN S.L.
info.emea@mgl-intl.com
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
You can download the complete manual
at the URL
https://clogic-intl.com/clogic-740-SD
AMERICAS: MGL AMERICA, LLC.
info.na@mgl-intl.com
US East Coast: 2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
Tel: +1 833 533-5899
US West Coast: 760 Challenger Street.
Brea, California 92821 USA
Tel: +1 310-728-6220
www.mgl-intl.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the 740-SD and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Clogic740sdcbint