DR2 Radius Dendrometer
When the sensor is correctly installed, it will function under outdoor conditions without the
need for further maintenance.
Depending on the growth rate of the tree, the sensor should be reset after some months
or years of measurements. When the output approaches 25 mm, the sensor needs to be
reset.
Relax the screw slowly so that the sensor rod is pushed in by about 2-3 mm. When the
reset is taking place shortly before frost period, the sensor rod should be pushed in by 5
mm. At frosts the stem diameter can shrink considerably.

7. Technical Specification

Name of the Sensor
Use area
Suitable for plant size Diameter > 8 cm
Limitation
Range of the senor
Resolution
Accuracy
Temperature coeffi-
cient of the sensor
Linearity
Environment
Weight of the sensor
Power supply
Material
Cable length
Radius dendrometer
Type DR2
For measuring radius growth of fast growing trees
Tree trunk is injured by drilling (the damage can be minimized if
using tree resin).
25.4 mm
The resolution of the sensor itself is infinite. The resolution of
readings is determined by connected data logger, e.g.
CR1000: 3.3 µm
Dendrometer logger DL18: 0.5 µm
Dendrometer dependent:
Max. ±1.97% of reading (stable offset)
Dependent on the connected data logger, e.g.:
CR1000:±(0.04% of reading+10µm)
Dendrometer logger DL18: ±0.1%
<0.2 µm / °C in the whole range
<0.7%
Outdoor condition: -25 to 70C air temperature, 0 to 100% relative
air humidity
33 g without cable
Stabilized Vex 0.5 – 10 VDC, power consumption practically zero
Stainless steel and Aluminium
5 m, extendable up to 100 m