TABLE OF CONTENTS ..................3 1. Before You Start ....................5 2. Product Description ..................5 2.1 Dimensions ........................8 G4SZV-2 & G4SDZV-2 (MKII) ....................8 2.2 Gas Flow Rates ......................... 9 2.3 Pipe Connection ........................ 9 2.4 Optical Port ........................9 2.5 Battery ..........................
Page 4
11. Communication Features and Functionality ..........34 12. Clock ......................35 13. SMETS2 ALERTS ..................35 14. FLONIDAN Alarms data logging ..............36 14.1 Data logging ........................36 14.2 ALERTS and event log ....................37 14.3 Battery Low Alarm ......................37 14.4 Out of range Alarm ......................
UTRN, these are known as Friendly credit periods and are decided by the utility alone), in addition special emergency credit facilities may be offered in certain circumstances. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 5...
Page 6
If the meter detects passing gas above a predefined rate, indicating a potential gas leak, it will close the valve. Checks should then be made to ensure gas appliances are turned off before a second attempt to open the valve is made. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 6...
Page 7
Physical Component Overview Electronic index A: G4SZV & G4SZV-1 (MKI) Verification Display seal Installation Optical port seals (side locks) Battery behind cover and label Press buttons Meter Serial Number (MSN) GUID (MAC NUMBER) B: G4SZV-2 & G4SDZV-2 (MKII) Display Installation...
Note: Only approved battery cells may be used in this product to maintain ATEX intrinsic safety certification. Please contact the Flonidan for the correct replacement battery. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10...
You will also find the unique Meter Serial Number (MSN) of the meter, in the form “G4F………..” below the display. There is also the Flonidan internal Part number in the form “P/N 115xxxxxxxx”, there is full traceability of the internal components of the meter from the either of these numbers.
All ok. If the symbol is not present, there is no connection to the HAN Information waiting (from gas Go to menu + Information, and scroll through the incoming meter) Information. Acknowledge with by pressing button below [i] Firmware download in progress G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 11...
Page 12
15 seconds. If this display has used its maximum amount of display time available (configuration setting) the display will not switch on for a period of time allowing the display time credit to build up again. This function is implemented to prevent customers draining the battery. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 12...
PIN Code! See section 8.2.8 on how to enter the code. The length of time for temporary access after PIN entry is 30 seconds after last interaction. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 13...
This wakes up the meter and it will check WAKE UP (only once per 30 for any pending messages. mins) This option will disappear for 30 mins once pressed. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 14...
Page 15
Tariff Switch between the 4 screens using ← → TOU PRICES in £/kWh for Price per Time period £/kWh in each tariff the form “x.yyyyy” Switch between the 4 screens using ← → G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 15...
Page 16
(billing) period ie Block USED (B1+B2+B3+B4) Duration: is days that this has taken / Total block days (billing Switch between the 6 screens period) using ← → (blank if no volume used yet) G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 16...
Page 17
← → EMERG. CREDIT NOTE! Status: Not Available/ only Available /in use/Exhausted shown Limit: This is the limit set by the Head End system prepay Remaining: This is the mode emergency credit remaining G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 17...
Page 18
GBCS alert list. GBCS table broken, ie 16.2 SECURITY the side Other info, if the event has a locks are byte removed, and the front cover is removed (as SMETS2 4.4.5 requirement) G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 18...
Page 19
File Name, internal reference the side Line no: The line in the code SYSTEM LOG locks are removed NOTE! This information is only and the front used by Flonidan for triage cover is work. removed This is an internal Flonidan NOTE...
Page 20
These options are only shown if the Meter has not yet been installed and paired. Cancel allows you to return to HAN STATUS the main DEVICE INFO menu Install HAN will start the install process. (see installation manual) G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 20...
Page 21
1 minutes the side and then close it again locks are In both cases it will show the removed, VALVE TEST COMPLETED and the front when it is finished. cover is removed (as SMETS2 G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 21...
Page 22
Or you can change the PIN code NOTE you need to know the current pin to be able to do If the PIN is this! active Correct entry of the PIN will disable the PIN usage G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 22...
Page 23
If you choose to CHANGE PIN CHANGE You will be asked to enter a new PIN as described in section 2.8.2 This information is set by the UTILITY or MAP from the Head End System (HES) CONTACT Contact Info G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 23...
Until you press this, you can go back and correct any false entries in the 20 digit code. And then go to the RHS to enter the UTRN Enter PIN 2.8.3.02 When entering a PIN code, the same method is used, except there are only 4 digits Enter PIN Code: G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 24...
Currency (£), and also the gas price for each block tariff may be seen. The consumption level, deciding which block tariff, B1-B4 to use, is determined by consumption limits, set up from head office. Block tariff counters, m Block tariff prices G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 25...
The system will generate an alarm if the wheel is rotating backwards or if the Gray code detected differs from the Gray code expected. Note! Reverse flow is physically blocked, so a reverse flow alert means the meter is broken and must be replaced. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 26...
These flow/error values make the “error curve”. Errors at flow rates that have not been determined at calibration are calculated by linear interpolation. Below Qmin and above Qmax the corrections from Qmin, resp. Qmax are used. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 27...
The index is able to compensate for minor known temperature effects on the cyclic volume. Temperature correction is based on 4 points: -25, 0, 30, 55°C Correction at each point may be up to ±4% Between the points, linear interpolation is used. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 28...
LCD. In addition, this alarm will be sent to the HES via the HAN. Metrologic seal behind cover Installation seals (side locks) Metrologic seal behind cover Installation seals (side locks) G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 29...
Position indication on LCD Reliable limit switch Leakage: < 1 L/h @ 75 mbar (acc. to EN 16314:2013) Pressure Drop : <2 mbar (air) at 6 m /h (meter + valve, acc. to EN 1359:1998) G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 30...
(Armed)) by entering a UTRN payment. The amount that needed to be added is the amount to take the credit level up to or above the disablement threshold (normally zero). G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 31...
The test period is set to 60 seconds Both of these values will be able to be updated from the Utility at a later date, when the DCC has removed a defect in its system. (circa end of 2018) G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 32...
Further CPA approved versions: 1. Index: 04.2400.10-1500 Radio: 3.10.8 OTA header 10030A08 (MKII): The version used for CPA approval is: Index: 04.2400.01-2200 Stack: 6.5.2 In SMETS2 this corresponds to the File Version in the OTA header 01040605. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 33...
The IR-head physical implementation is in accordance to EN61107. Wireless ZigBee Integrated ZigBee radio, 2.4MHz. or Sub GHz (868 MHz) Communication protocol according to SEP 1.X (depending on latest SMETS requirement) G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 34...
The Alerts in SMETS 2 are defined by the GBCS Table 16.2 Mandatory and Non-mandatory ALERTS All mandatory alerts are supported by the Flonidan G4SZV-1 and G4SZV-2 & G4SDZV- 2SMETS2 meter. Most of the non-mandatory alerts are also supported a full list can be found in the Customer card.
Flonidan Customer Card FLONIDAN Alarms data logging In addition to the GBCS required alerts, Flonidan have implemented an ALARM system which also logs the alarms, this is helpful to the end user and the manufacturer for triage work.
Consumption is calculated from these activities: Base consumption (measured with flow) Radio/ZigBee activity Communication Valve operations Display Backlight Buzzer Battery exchange 15.2 Please refer to the separate Battery Exchange manual for full instructions on this subject. G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 37...
Electronics Equipment (WEEE) and must be handled according to the directive, when it’s disposed of. Cleaning 15.7 As indicated on the Index label: CAUTION! Static hazard. Clean only with a damp cloth Storage 15.8 Temperature range: -40 to +60°C Humidity: <93 %RH, non-condensing G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 38...
Head End System or DCC Adaptor Home Area Network UTRN Universal Transaction Reference Number Liquid Crystal Display Advanced Encryption Standard firmware Over The Air ATEX Standard for Equipment in Explosive atmospheres Measuring Instrument Directive G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10 Page 39...